JET JCT-2610 , 11" Rivet Buster

Manual - Page 8

For JCT-2610.

PDF File Manual, 16 pages, Download pdf file

Loading ...
Loading ...
Loading ...
8 JCT-2610 Series Rivet Buster
Air System Recommendations
Equip the air compressor intake with a
replaceable air filter that can be easily cleaned.
Use safety shut-off valves so air flow can be
stopped quickly in case of a line break.
When using multiple hoses, air hoses should be
larger than leader hose. Join multiple hoses
directly, rather than with quick connect fittings
which may cause pressure drops and tool power
reduction.
Use anti-whip devices across hose couplings to
prevent hose from whipping in the event of a hose
failure or coupling disconnect.
Always use moisture traps at the compressor for
the main distribution line. Use moisture traps and
in-line oilers on each downline that is to be used
for air tools. (See Figure 4). Place oiler as close to
air tool as possible for best lubrication.
Lubrication
Use a light oil containing rust inhibitors, identified
as “Air Tool Oil,” or an ISO VG32 (SAE 10W)
equivalent. Many JET air tools have integral oil
reservoirs, which should be kept filled when in-line
oilers are not used.
If greasing is required, use a grease that is highly
water resistant for the front case components on
air impact wrenches, grinders and sanders.
Recycling
Protect the environment. Your tool contains
materials which can be recovered or recycled.
When its useful life has expired, please leave tool
at a specialized facility.
Figure 3
Recommended arrangement of air piping and air line system