Broilmaster BSABF12N 12 Inch Slide-In Double Side Burner

Care & Use / Installation Manual - Page 12

For BSABF12N.

PDF File Manual, 32 pages, Read Online | Download pdf file

BSABF12N photo
Loading ...
Loading ...
Loading ...
GAS REQUIREMENTS
Type 1 connection
per ANSI Z21.58b-2012/CSA
1.6b-2012
Quick
Coupling
Nut
Gas Requirements And Hook-up
LP GAS MODEL ONLY - TYPE 1
CONNECTION WITH REGULATOR
AND HOSE TO YOUR LP GAS TANK.
Connect and tighten the swivel nut of the gas
hose to the Gas Appliance manifold shown
below.
Turn all Control Knobs to the OFF position.
Inspect the valve connection port and
regulator assembly for damage or debris.
Remove any debris. Never use damaged
equipment.
Connect the regulator assembly to the tank
valve and HAND TIGHTEN nut clockwise to a
full stop. DO NOT use a wrench to tighten
because it could damage the Quick Coupling
Nut and result in a gas leak/fire hazard.
Open the tank valve a full turn
(counterclockwise) and use a soapy water
solution to check all connections for leaks
before attempting to light your Gas Appliance.
See
"Check All Connections for LP Gas Leaks." If a
leak is found, turn the tank valve off and do not
use your Gas Appliance
until the leak is
repaired.
LP Gas Tank
NOTE: No Appliance
Regulator Is Used When
An LP Tank And Type 1
Connector And Regulator
Are Used.
Page 12
PREMIUM GRILLS
CHECK ALL CONNECTIONS
FOR LP GAS LEAKS.
Never test for leaks with an open ame.
Prior to rst use, at the beginning of each
season, or every time your LP Gas tank is
changed, you must check for gas leaks.
FOLLOW THESE THREE STEPS:
1. Make a soap solution by mixing one part
liquid detergent and one part water.
2. Turn the grill Control Knobs to the full OFF
position, then turn the gas ON at source.
3. Apply the soap solution to all gas
connections. If bubbles appear in the
soap solution the connections are not
properly sealed. Check each tting and
tighten or repair as necessary.
with Hose
(LPG)
Regulator
Gas Valve/
Manifold
Assembly
Loading ...