9
NOTE:
It is most important that this target top is installed correctly and that operation is correct
before use. Installation shall comply with local gas, health and safety requirements.
This appliance shall be installed with sufficient ventilation to prevent occurrence of
unacceptable concentrations of health harmful substances in room, the appliance is
installed in.
Waldorf Target Tops are designed to provide years of satisfactory service, and correct installation is
essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas and fire safety.
Australia / New Zealand: - AS/NZS5601 - Gas Installations.
United Kingdom: - Gas Safety (Installation & Use) Regulations 1998.
- BS6173 - Installation of Catering Appliances.
- BS5440 1 & 2 - Installation Flueing & Ventilation.
Ireland: - IS 820 - Non - Domestic Gas Installations.
Installations must be carried out by authorised persons only. Failure to install equipment to
relevant codes and manufacturers specifications shown in this section will void the warranty.
Components having adjustments / settings protected (e.g. paint sealed) by the manufacturer
are only to be adjusted by an authorised service agent. They are not to be adjusted by the
installation person.
Remove all packaging and transit protection from appliance including all protective plastic coating
from exterior stainless steel panels.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
Ensure the 4 adjustable feet are fitted with protruding centre screw. (Not fitted on RN8100G - RB
Models).
Report any deficiencies to distributor who supplied appliance.
Check available gas supply is correct to as shown on rating plate. Refer to Dimensionssection for
rating plate locations for different models.
1. Installation must allow for a sufficient flow of fresh air for combustion air supply.
2. Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3. Never directly connect a ventilation system to appliance flue outlet.
4. Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation. Minimum installation clearances shown overleaf are to be adhered to.
5. Position target top in its approximate working position.
6. All air for burner combustion is supplied from beneath appliance. Legs must always be fitted and no
obstructions placed on or around base of appliance, as obstructions will cause incorrect operation
and / or failure of appliance.
NOTE: Do not obstruct or block appliances flue. Never directly connect a ventilation system to
appliance flue outlet.
Combustion Air Requirements:
Natural Gas 12 m
3
/hr
LPG 12 m
3
/hr
Town Gas 12 m
3
/hr