DRAPER 22108 12/24V Diesel Transfer Pump

Original Instructions - Page 6

For 22108.

PDF File Manual, 20 pages, Read Online | Download pdf file

22108 photo
Loading ...
Loading ...
Loading ...
– 6 –
Input voltage (V) Flow rate (L/min) Absorption (AU) Pressure (bar)
Position A

12 35 8 0.5
24 72 15 0.5
Position B
(rated conditions)
12 33 11 1
24 66 19 1.2
Position C
(Bypass mode)
12 0 16 2
24 0 25 2.6
4.4 Performance

These values are achieved in the following
operating conditions:
Ambient temperature: 20°C
Pump position: The hose length and position of

of 0.3bar at the nozzle.
Changing these conditions may result in higher pressure


For optimal performance, the loss of suction pressure
should be reduced as much as possible. This can be
achieved using the following methods:
Shorten the hose as much as possible.
Avoid the use of elbows and throttling in the hoses.
 
Use hoses with as large a diameter as possible.
Important: The burst pressure of the pump is 20bar.
Back Pressure
0
Flow rate (L/min)
4. Product Introduction