– 6 –
Input voltage (V) Flow rate (L/min) Absorption (AU) Pressure (bar)
Position A
12 35 8 0.5
24 72 15 0.5
Position B
(rated conditions)
12 33 11 1
24 66 19 1.2
Position C
(Bypass mode)
12 0 16 2
24 0 25 2.6
4.4 Performance
These values are achieved in the following
operating conditions:
• Ambient temperature: 20°C
• Pump position: The hose length and position of
of 0.3bar at the nozzle.
Changing these conditions may result in higher pressure
For optimal performance, the loss of suction pressure
should be reduced as much as possible. This can be
achieved using the following methods:
• Shorten the hose as much as possible.
• Avoid the use of elbows and throttling in the hoses.
• Use hoses with as large a diameter as possible.
Important: The burst pressure of the pump is 20bar.
Back Pressure