Waldorf RNB8813G Bold 1200mm Gas Range Static Oven

Installation Operation Manual - Page 6

For RNB8813G.

PDF File Manual, 32 pages, Read Online | Download pdf file

RNB8813G photo
Loading ...
Loading ...
Loading ...
4
Specifications
Gas Supply Requirements
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P
(20, 37).
Flue Type: A
1.
* Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set through the appliance regulator and is not to be
adjusted, apart from when carrying out gas conversion, if required. (Refer to ‘Gas
Conversion’ section for details).
Natural Gas (G20) Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Oven Open Burner
(each)
Griddle
(each 300mm section)
Oven
Heat Input
(nett)
Nominal 6.5 kW 5.5 kW 7.8 kW 6.5 kW 5.5 kW 7.8 kW
Reduced 1.75 kW 1.85 kW --- 1.75 kW 1.95 kW ---
Gas Rate
(nett)
Nominal 0.69 m
3
/hr 0.58 m
3
/hr 0.83 m
3
/hr 0.51 kg/hr 0.43 kg/hr 0.61 kg/hr
Reduced 0.19 m
3
/hr 0.20 m
3
/hr --- 0.14 kg/hr 0.15 kg/hr ---
Supply Pressure
20 mbar 37 mbar
Burner Operating
Pressure (*)
9.5 mbar 26 mbar
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
- Oven 30 MJ/hr 30 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.95 kPa 2.6 kPa
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas LP Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
- Oven 30 MJ/hr 30 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.95 kPa 2.6 kPa
Gas Connection
3
/
4
” B.S.P. Male
Loading ...
Loading ...
Loading ...