Haier 1U24LP2VHA FlexFit Series 208-230V 24,000 BTU Ductless Mini-Split Outdoor Heat Pump System

User Manual - Page 41

For 1U24LP2VHA.

PDF File Manual, 121 pages, Read Online | Download pdf file

1U24LP2VHA photo
Loading ...
Loading ...
Loading ...
39
FlexFit Pro
Model Name
System AM36LP
Outdoor 1U36LP2VHA
Indoor AM36LP2VH*
Cooling
Rated Capacity Btu/hr 35000
Capacity Range Btu/hr 8500-37500
Rated Power Input W3,500
SEER 17
EER 10
Moisture Removal Pt./h 6.8
Heating
Rate Heating Capacity 47°F Btu/hr 37500
Heating Capacity Range Btu/hr 8500-41000
Rated Power Input W3,283
HSPF 10.5
Operating Range Cooling °F(°C) 0~115F(-18-46C)*
Heating °F(°C) -4°F~75°F -20-24℃)
Power Supply Voltage, Cycle, Phase V/Hz/- 208-230/60/1
Outdoor Unit
Compressor Type DC Inverter Driven Rotary
Maximum Fuse Size A 30
Minimum Circuit Amp A 26.0
Outdoor Fan Speed RPM 750/700/650/600/500/400/300
Outdoor Noise Level dB 52
Dimension: Height in (mm) 38 (965)
Dimension: Width in (mm) 37 3/8(950)
Dimension: Depth in (mm) 14 5/8(370)
Weight (Ship/Net)- lbs (kg) 207.2/180.7 (94/82)
Indoor Unit
Fan Speed Stages 4 + Auto
Airow (Turbo/High/Med/Low/Quiet) CFM 1100/950/735/675
Motor Speed (Turbo/High/Med/Low/Quiet) RPM 1000/920/860/810
Indoor Sound Level dB (Turbo/High/Med/Low/Quiet) 32/28/25/23
Dimension: Height in (mm) 9 7/8 (250)
Dimension: Width in (mm) 59 (1500)
Dimension: Depth in (mm) 28 3/8 (720)
Max. External Static Pressure in.W.G(Pa) 0.6(150)
Drainpipe Size O.D. in 1 1/4
Internal Condensate Pump Standard
Max. Drain-Lift height in(mm) 27 9/16(700)
Grill Model NA
Grill Dimension: Height in (mm) NA
Grill Dimension: Width in (mm) NA
Grill Dimension: Depth in (mm) NA
Weight (Ship/Net)- lbs (kg) 130.1/121.3 (59/55)
Refrigerant Lines
Connections Flare
Liquid O.D. in 3/8
Suction O.D. in 5/8
Factory Charge Oz 88.2
Maximum Line Length Ft / m 165/50
Maximum Height Ft / m 100/30
Loading ...
Loading ...
Loading ...