Remove wiring cover from rough-in plate or electrical compartment and set aside.
INTERNAL BLOWERS: Connect cable into wiring box using wire connectors.
Connect BLACK to BLACK, WHITE to WHITE and GREEN
or bare wire under GREEN ground screw.
Reinstall wiring cover.
IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.
HD0580
PLATE ON HOOD BACK
LOCKNUTS
WIRING
COVER
LOCKNUTS
ROUGH-IN PLATE
ON
HOOD TOP
INTERNAL BLOWER(S) ONLY
Run power cable to installation location. Remove the electrical compartment
cover. Insert the cable in the hood and tighten the wire clamp to secure the cable.
ALL INSTALLATIONS
Rest the back cavity of the hood against the wood mounting strip.
Secure the hood to wood mounting strip with 4 screws no. 8 x 3/4" (for 30" and 36" width hoods) or 6 screws (for 42" and 48" width hoods)
provided at locations shown. Drill three 3/16" sized holes into the drywall for wall anchors through the existing holes in the hood back in the
locations shown. Then, install the three wall anchors with the remaining no. 8 x 3/4" screws and the 3 washers provided.
12. INSTALL THE HOOD
CAUTION
Hold the hood until it is completely secured to the wood
mounting strip.
HD0579
WALL ANCHORS LOCATION
MOUNTING SCREWS LOCATION
13. ROUGH-IN PLATE LOCATION (EXTERNAL BLOWERS HOODS ONLY)
For ducting through hood top, existing plate remains in place inside the hood
back.
For ducting through hood back, remove existing plate from inside hood back and
remove the rough-in plate from the hood top. Attach the plate to inside hood top
to cover hole. Secure to threaded studs with same 4 nuts. Install the rough-in
plate to hood back so that the wiring box is located on the right side when facing
the hood.
Connect ducting to rough-in plate when installing the rough-in plate. Use metal
foil duct tape to make all joints secure and air-tight.
14. CONNECT THE WIRING (ALL BLOWERS)
WARNING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power to be switched on accidentally.
!
CAUTION
The ORANGE wire (A) is for make-up air device connection only. If
there is no make-up air device, never remove the cap on the ORANGE
wire end.