38
11. Technical Data
This cooker is designed for use on Natural Gas, although a
conversion for LP (
LPG X Propane (2.54 kPa)
) gas is packed with the
cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: Australia
Connections
Gas (Rp ½ at rear right-hand side) Electric
Natural gas 1 kPa 230 V 50 Hz
Propane 2.54 kPa
See the appliance badge for test pressures.
Dimensions
Overall height minimum 900 mm maximum 925 mm
Overall width 1100 mm
Overall depth 600 mm (to fascia); 650 mm (over handles)
Minimum space above the hotplate 650 mm
Refer to 'Positioning the Cooker'.
Ratings
Natural Gas 1.0 kPa LP Gas 2.54 kPa
Hotplate
Injector Bypass Injector Bypass
Wok burner
15.2 MJh
-1
internal 112
90 15.0 MJh
-1
internal 66
54
external 164 external 91
Large Burner
12.3 MJh
-1
165 80 12.0 MJh
-1
89 41
Medium Burners
6.2 MJh
-1
115 56 6.2 MJh
-1
67 33
Small Burner
3.7 MJh
-1
92 48 3.3 MJh
-1
45 25
Ovens 9.5 MJh
-1
160 70 9.5 MJh
-1
87 79
Grill
10 MJh
-1
280 77 10 MJh
-1
100 96
Warmer 160 W
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.) : 0.18 kW.
ArtNo.105-0008 - Technical data - 90 induction - Elan