Broan AER110RGBLC ChromaComfort 110 CFM Ventilation Fan with 24 Color Selectable LED, 1.5 sones, ENERGY STAR Certified

Installation Guide

For AER110RGBLC.

PDF File Manual, 12 pages, Read Online | Download pdf file

AER110RGBLC photo
1
OPTION - To mount housing anywhere between ceiling framing:
Use optional Hanger Bar Kit (sold separately from local distributors
or website). Follow mounting instructions included with kit.
ROOF CAP* (with built-in damper)
WALL CAP*
(with built-in
damper)
4-IN. ROUND
ELBOWS*
FAN
HOUSING
Seal gaps
around
housing.
Seal duct joints
with tape.
INSULATION
(Place around and
over fan housing.)
POWER
CABLE *
* Purchase separately.
OR
Keep duct
runs short.
4-IN. ROUND
DUCT*
IMPORTANT -
The ducting from this fan to the outside of the
building has a strong effect on the air flow, noise and energy use of
the fan. Use the shortest, straightest duct routing possible for best
performance, and avoid installing the fan with smaller ducts than
recommended. Insulation around the ducts can reduce energy loss
and inhibit mold growth. Fans installed with existing ducts may not
achieve their rated airflow.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer at the address or telephone number
listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock
the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s)
in accordance with all applicable codes and standards, including fire-rated
construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer’s guideline and safety standards
such as those published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground
Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive
materials and vapors.
2. This product can be installed in a wall if mounted 8-ft. or more above the floor.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep
drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and
requirements.
READ AND SAVE THESE INSTRUCTIONS
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance
- lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace the
blower assembly (includes motor and impeller).
OPERATION
The Chroma Fan/Light must be operated using only the wall control
included. See separate operating instructions. DO NOT operate the
Chroma Fan/Light with any other switches or controls.
For Warranty Statement, Service Parts, Technical Support, or to
Register your product, please visit our website or call:
In the United States - broan-nutone.com 800-637-1453 or
888-336-6151. In Canada - broan-nutone.ca or 877-896-1119
ChromaComfort
TM
Fan/Light Installation
The Bluetooth
®
word mark and logos are registered trademarks owned by Bluetooth
®
SIG, Inc. and any use of such marks by Broan-NuTone LLC is under license. Other
trademark and trade names are those of their respective owners.
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules and RSS-210 of Canada. Operation
is subject to the following two conditions:
(1) This device may not cause interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation. FCC
IDs: 2ADLL-RGB001 & 2ADLL-RGB002 IC IDs: 2143B-RGB001 & 2143B-RGB002
This Bluetooth
®
wireless technology enabled luminaire complies with FCC radiation
exposure limits set forth for an uncontrolled environment. End users must follow the
specific operating instructions for satisfying exposure compliance. This luminaire must
not be co-located or operate in conjunction with any other antenna or transmitter.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Loading ...
Loading ...
Loading ...

Other documents for Broan AER110RGBLC

The following documents are available:
Installation Instruction Specification
  • Specification Sheet - (English) Download
Other Documents
  • Brochure - (English) Download
  • ChromaComfort App Instructions - (English) Download
Photos

Specifications