19
GENERATING SET MAINTENANCE
WARNING: Never clean the generator when it is running! Never use water to clean the
generating set. Water can enter the generating set through the cooling slots and damage the
generating set windings.
WARNING: Do not modify the generator in any way. Do not tamper with governed speed.
Generator supplies correct rated frequency and voltage when running at factory set. Tampering
with the factory set governor will void your warranty.
Make certain that the generator is kept clean and stored properly.
Use a damp cloth to clean exterior surfaces of the generating set. Use a soft brush to clean the dirt and
oil.
Use an air compressor (25 PSI) to clear dirt and debris from the generating set.
Inspect all air vents and cooling slots to ensure that they are clean and unobstructed.
ENGINE MAINTENANCE
Changing the oil
WARNING: Change the oil when the engine is warm form operation. The oil can reach up to
140under that condition. Careful operation should be taken to prevent burns.
1. Place the machine on a level surface which is 300mm higher than the ground.
2. Remove the right cover.
3. Place the waste oil box on the ground.
4. Remove the oil dipstick, and tilt the machine to pour the oil.
5. Add recommended oil to the upper limit.
6. Fully tighten the dipstick.
7. Properly dispose of any used oil at an approved waste management facility.
8. Reinstall the oil maintenance cover.
AIR FILTER
WARNING: Do not run the engine without the air filter, or
serious danger can result.
Routine maintenance of the air cleaner helps maintain proper
airflow to the carburetor. Occasionally check that the air cleaner is free of
excessive dirt.
1. Remove the air filter maintenance cover.
2. Loose the filter fix clamp and remove the cover of the air filter.
3. Remove the foam filter element.
4. Wash in liquid detergent and warm water.
5. Squeeze thoroughly dry in a clean cloth.
6. Saturate in clean engine oil.
7. Squeeze in a clean , absorbent cloth to remove all excess oil.
8. Assemble the filter element onto the filter unit.
9. Assemble the filter fix clamp.
10. Reinstall the air filter maintenance cover.
Loading ...