Installation
11
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY A QUALIFIED
PERSON.
Each appliance should be connected to an adequately
protected power supply and isolation switch mounted
adjacent to, but not behind appliance. This switch must be
clearly marked and readily accessible in case of fire.
1. Check electricity supply is correct as shown on Rating
Plate attached to lower front hand side of front sill
panel.
2. Supply terminal connections are located at rear of
appliance. Refer to ‘Electrical Connections’ in
‘Dimensions’ section of manual.
3. Open oven door and remove oven control panel to
allow connection access for electrical supply.
4. Connect mains supply to L1, L2 and L3 connection
terminals. Refer to 'Electrical Supply Requirements'
section for connection details.
NOTE: This appliance can be converted from 3 Phase to Single Phase supply by connecting single
phase input to L1 and adding a bridge wire between L1, L2 and L3 connections, (refer to Fig
3 overleaf and information shown in 'Electrical Supply Requirements Table' in
'Specifications' Section).
5. Connect neutral and earth conductors to neutral stud and earth stud respectively.
6. For all connections ensure conductors are secure and appropriately terminated.
7. Tighten cable gland to secure against tension on cable.
8. Check that the polarity of each connection is correct to the mains connection terminals markings on
the appliance.
NOTE:
 Appliance must be earthed.
 Fixed wiring installations must incorporate an all-pole disconnection switch.
9. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
appliance is level and at correct height.
10. Connect power supply to appliance.
11. Check electrical supply is within input rating specification, refer to ‘Specifications’ section).
Neutral supply
connection to N
Phase supply
connection to L1
P
N
Fig 4
Add bridging
wires between
L1, L2 and L3.
THIS APPLIANCE MUST BE EARTHED. IF SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.
Warning
Changing supply from 3 phase to single phase will increase electrical current
loading on supply cable. Ensure supply cable used is of a sufficient size for
current loading, refer to 'Electrical Supply Requirements' table.