Installation
Instructions
TroubleshootingWasher CareWasher Use
Min 60
Max 100
B
Min.60cm
Max.100cm
C
28
" min.
(710 mm)
D
Washer
Safety
Operation
Requirements
Min 60
Max 100
B
Min.60cm
28” min.
(710 mm)
GROUNDING REQUIREMENTS
Improper connection of the equipment grounding conductor can result in a
risk of electrical shock. Check with a licensed electrician if you are in doubt
as to whether the appliance is properly grounded.
1. The appliance MUST be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electrical shock by
providing a path of least resistance for electrical current.
2. Since your appliance is equipped with a power supply cord having an
equipment-grounding conductor and a grounding plug, the plug MUST
be plugged into an appropriate, copper-wired receptacle that is properly
installed and grounded in accordance with all local codes. If in doubt,
call a licensed electrician. DO NOT cut o or alter the grounding prong
on the power supply cord. In situations where a two-slot receptacle is
present, it is the owner’s responsibility to have a licensed electrician
replace it with a properly grounded grounding-type receptacle.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucet MUST be installed within 42” (107 cm) of your
washer’s water inlet. The faucet MUST be 3/4” (1.9 cm) garden hose-type
so inlet hoses can be connected. Water pressure MUST be between 20 and
100 psi. Your water department can advise you of your water pressure.
DRAIN REQUIREMENTS
1. Drain capable of eliminating 64.3 L per
minute.
2. A standpipe diameter of 1-1/4” (3.18 cm)
minimum.
3. The standpipe height above the floor
should be: Minimum height: 24” (61 cm)
Maximum height: 40” (100 cm)
4. to drain into a laundry tub; tub needs to
be min 20 gal (76 L), top of the laundry
tub must be min 24” (61 cm)
5. Floor drain requires a min 28” siphon
drain (710 mm) from the bottom of the
unit
C
D
7