1) The pump must be installed in a position below the tank intake (with a
positive head).
2) The tank must have baffles to prevent water splashes and its capacity
must be at least 10 times greater than the pump's rated displacement.
3) The vacuum measured directly at the pump intake port must not exceed
0.1 bar and the water temperature must not be above 30 .
4) Adopt all the precautions described in the"General Guidelines on Water
Connections" section. The following is a simplified illustration of the
layout for the connection of the pump to a tank.
A) Tank
B) Intake filter
C) High pressure pump
D) Pressure gauge
E) Pressure damper
F) Relief valve(by-pass valve)
G) Dump pipeline
H) Nozzle
I) Shut-off valve