Ifconnectingbydirectwire:
Powersupplycablemustmatchpowersupply(4-wireor3-wire)
andbe:
[] Flexiblearmoredcableornonmetallicsheathedcoppercable
(withgroundwire),protectedwithflexiblemetallicconduit.All
current-carryingwiresmustbeinsulated.
[] 10-gaugesolidcopperwire(donotusealuminum).
[] Atleast5ft(1.52m)long.
[] Tosupplytherequired4wire,singlephase,120/240volt,60
Hz.,AConlyelectricalsupplyonaseparate30-ampcircuit,
fusedonbothsidesoftheline.Atime-delayfuseorcircuit
breakerisrecommended.Connecttoanindividualbranch
circuit.
[] ThisdryerisequippedwithaCSAInternationalCertified
PowerCordintendedtobepluggedintoastandard14-30R
waltreceptacle.Thecordis5ft(1.52m)inlength.Besure
wattreceptacleiswithinreachofdryer'sfinallocation.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
[] For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on
the dryer.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
[]
4-wirereceptacle(14-30R)
Do not use an extension cord.
If you are using a replacement power supply cord, it is
recommended that you use Power Supply Cord Replacement
Part Number 9831317. For further information, please
reference the service numbers located in the "Assistance
or Service" section.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE INSTRUCTIONS
It is your responsibility
[]
[]
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code, C22.1-1atest
edition and all local codes. A copy of the above codes
standard may be obtained from: Canadian Standards
Association, 178 Rexdate Blvd., Toronto, ON M9W 1R3
CANADA.