Aboutthe controlsonyourZoneline. ge.com
_m HIGH
= =
I;_-I:_-ll- 0w
m_ AUTO
TEMP FAR
_nCOOL
_nFAN
"=="HEAT I !
MODE SLEEPOPERATION
TEMPCONTROL FAN,MODE& SLEEPOPERATION
@
TempControl
The temp control is used to maintain the
@
To cancel the sleep mode, press the MODEpad or
the SLEEPpad a second tiine.
I'OOIIl teillpei'attli'e. The coiili)i'essoi" will
cycle on and off to keep the room at the
same level of corot)ft.
Press the + pad to raise the temperature.
Press tile - pad to lower tile temperatm'e.
_,_]/en tile outdoor temi)eratm'e is lower than
25°E heat is provided b)' tile electric heater in tile
air conditioner instead ot by tile heat pump.
Sleep
Press to set the air conditioner to run fi)r
8l/om_ boil)re it automatically returns to
tile I)revious setting.
_A]/en in tile cooling mode and tile
sleep timer is set, tile set temperatm'e will
automatically increase 2°F after tile second
hour then 1 °F each hour over tile next two
hom_. Also, tile em speed will change to
low. \._l/en in the heating mode, the set
temperatm'e will decrease in tile same
iilannei i
@Fan, Mode & Operation Control
FAN--s'ets tile tim operation fin" HIGH,
LOWer AUTO speed. When set at AUTO,
it automatically switches between LOW
and HIGH as room temperature changes.
MODE--COOL--For cooling
FAN--For fim-onl_ operation
HEAT--For heating
OPERATION--ON/STOP--Turnstile unit
on oi" olC[. Power I'eIl/}lins connected to tile
Zoneline. Tile Freeze Sentinel teatm'e still
flmctions if switch 6 is enabled (UP). See
tile Freeze Sentinel section.
NOTE: Thetemperaturedisplaywill flash to
indicateapossible unit malfunction. Seethe
Before you call for service section.
About YourHeat Pump
Heat I)umps can save money by removing heat
fl'om tile outside air----even when tile outside
temi)erature is below fl'eezing-- and releasing
that heat indom_.
To get tile best i)e_tommnce fl'om your heat
i)ump, don't change tile room them/ostat ve_ T
often. Raising the heat setting 2-3 degrees will
cause the Zoneline to use its electric heating
elements in order to reach tile new temperatm'e
setting quickly:
There is a three minute minimum compressor
run time at any setting to prevent shmt cycling.
Tile indoor tim motor starts befln'e tile
COIlll)I'essoI" and stops aJ[teI" tile COIl/l)I'essoI"
cycles off'.
The electric heating elements use much
more electfidtv than heat i)umps and cost
II/OI'e to operate.
3