CLEANING
• Always unplug the unit before servicing in any way.
GENERAL CLEANING
• Inside the base of the unit. Pourexcesswateroutoftheunit.Washouttheunitwithfresh
water using the cleaning brush and a soft cloth as needed. Do not submerse the base of the
unit into water, or allow water to enter inside the dry air exhaust port of the unit.
• Water tank. Emptywatertank.Removemistnozzleandcleanthemisttubewithfreshwater
and a light brush (bottle cleaning brush is recommended).
• Outer surface of the unit. Wipe the surface of the unit with a soft, damp cloth if needed. If
you notice an accumulation of water during usage, reduce humidity and dry outer surface with
a cloth.
DESCALING
• Depending on usage and water type, cleaning to remove scale may be required
weekly or every other week to optimize unit performance.
• Ifyouliveinahardwaterarea,werecommendtheuseofdistilledwaterforyour
humidifier. This will help reduce the precipitation of minerals or ‘white dust’.
• Donotcleantheunitorwatertankwithdetergentsorcleaningchemicalsofanykind.
ULTRASONIC DISK
1. Unplug unit.
2. Remove the tank and empty all water from unit base and tank.
3. Locate the ultrasonic disk on the inside center of the base unit.
4. Use ONLY the enclosed cleaning brush to gently clean disk and remove build up and deposits.
Do not scrub or scrape the ultrasonic disk.
CLEANING
2. Open the tank lid, turning it
to the left.
3.
Pour cool, clean water directly
intothetank.Donotpouranything
but water into the tank.
5. Plug Power Adapter into back of
humidifier unit. Plug into outlet.
6. PressthePowerButtontoturnon.
*See Mode Chart for further operating
instructions.
SET UP
Selectarm,level,atlocation-atleastsixinches(15cm)fromanywallorobjectforproperair
ow.Placethehumidieronawater-resistantsurface,aswatercandamagefurnitureandsome
ooring.Donotplaceunitdirectlyoncarpet,towels,blanketsorotherabsorbentsurfaces.
Guardian Technologies will not accept responsibility for damage caused by water spillage.
FILLING
Make sure unit is unplugged.
DIRECTIONS FOR USE
1. Separate the tank from the base of the unit.
4.
Close the tank lid, turning it to the
right. It is important to FIRMLY secure
cap after filling the tank with water.
*Clean the disk with the
brush only. No other
cleaning tool should
beused.BRUSHONLY.
Ultrasonic Disk
If scale becomes difficult to remove with brush:
1.FilltheBasewith:mixtureof1tsp.whitevinegarand1tsp.water.
2. Let solution stand for 5 minutes.
3.WiththevinegarintheBase,cleanallinteriorsurfaceswithasoftclothorbrushtohelp
remove scale.
NOTE: If you live in a hard-water area, we
recommend the use of distilled water for
your humidifier. This will help reduce the
precipitation of minerals or ‘white dust’.