Foxwell I70PRO Premier Diagnostic Platform

User Manual - Page 16

For I70PRO.

PDF File Manual, 82 pages, Read Online | Download pdf file

I70PRO photo
Loading ...
Loading ...
Loading ...
16
Premier Diagnostic Platform User's Manual V1.01
2.4 Technical Specifications
Table 2-2 Technical Specifications
3 Getting Started
This section describes how to power on/off the scanner, provides brief
introductions of applications loaded on the scanner and display screen layout
of the scan tool.
3.1 Powering up the Scanner
Before using the i70Pro applications (including updating the scanner), please
make sure to provide power to the scanner.
The unit operates on any of the following sources:
Internal Battery Pack
External Power Supply
Item
Description
Touch Screen
8’’ diagonal, daylight readable color LCD screen, 1280*800 pixel
Operation
System
Android
Processor
MT8163 (ARM Cortex, a53x4, 1.3GHz)
Memory
2GB DDR3L
SSD Hard drive
32GB
System Type
32-bit operating Systems, x64-based processor
Display
Backlit 1280*800 pixel 8” LED capacitive touch screen
Communication
interface
Built-in WIFI 802.11 b/g Wireless LAN
USB2.0 OTG/standard USB 2.0 HOST
Bluetooth 4.0 (10-20 m)
Camera
5 megapixels rear-facing
Built-in Battery
8000mAh, Lithium-polymer battery, chargeable via 5V/3AUSB power
supply
Protocols
ISO9141-2, ISO14230-2, ISO15765-4, K/L lines, Double K Line
SAE-J1850 VPW, SAE-J1850PWM, CAN ISO 11898, High-speed,
Middle-speed, Lows-peed and Single wire CAN, KW81, KW82, GM
UART, UART Echo Byte Protocol, Honda Diag-H Protocol, TP2.0, TP1.6,
SAE J1939, SAE J1939, SAE J1708, Fault-Tolerant CAN
Dimensions
230*155*21mm (L*W*H)
Loading ...
Loading ...
Loading ...