Loading ...
Loading ...
Loading ...
DISPLAY LAMP BRIGHTNESS ADJUSTMENT
15
To decrease the display lamp brightness or turn it off.
1. Press and hold
)$1
for 3 seconds until brightness level ( , ,
or ) is shown on remote control LCD then release the button.
2. Press
Rise
or
Decrease
to adjust brightness in 4 levels.
Remote control
LCD
Operation display Brightness
Lamp illuminates full brightness.
100%
Lamp illuminates 50% brightness.
50%
Lamp illuminates 50% brightness and the
operation lamp is turned off.
50%
All lamps are turned off.
All turned off
In the examples of
and , the lamp illuminates for 5 seconds before
going off.
16
SELF CLEANING OPERATION
(COOL AND DRY OPERATION ONLY)
17
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
more 2 times
within 30 seconds.
TEMPORARY OPERATION
18
In case of the misplaced or discharged remote control
Pressing the RESET button, the unit can start or
stop without using the remote control.
Operation mode is set on AUTOMATIC operation,
preset temperature is 24°C and fan operation is
automatic speed.
REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the
pencil. “00” will be shown on the display. (Picture 1)
4. Press
02'(
during pushing . “B” will show on the display and
“00” will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized. (Picture 2)
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
OPERATION AND PERFORMANCE
20
1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating
operation starts.
3. Warm air control: When the room temperature reaches the set
temperature, the fan speed is automatically reduced and the outdoor unit
will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into
the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit
where it will not be subjected to snow drifts, accumulation of leaves or
other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is normal
because the cracking sound may be caused by expansion/contraction of
plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature Room Temperature
Heating –15°C ~ 24°C Less than 28°C
Cooling –10°C ~ 46°C 21°C ~ 32°C
Dry –10°C ~ 46°C 17°C ~ 32°C
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when
needed.
No benzine, thinner, polishing powder or chemically-treated duster.
Air lters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air lters.
3. Vacuum or wash and then dry them.
4. Reinstall the air lters and close the air inlet grille.
MAINTENANCE
21
1
2
The unit does not operate.
Cooling or Heating is abnormally low.
The power main switch is
turned off.
The circuit breaker is activated
to cut off the power supply.
Stoppage of electric current
ON timer is set.
The lters are blocked with dust.
The temperature has been set
improperly.
The windows or doors are opened.
The air inlet or outlet of the outdoor
unit is blocked.
The fan speed is too low.
The operation mode is FAN or DRY.
POWER SELECTION function is
set 75% or 50% (This function is
depend on remote controller).
TROUBLESHOOTING (CHECK POINT)
22
AUTO RESTART FUNCTION SETTING
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
Information
The product is shipped with Auto Restart function in the ON position.
Turn it OFF if this function is not required.
How to turn OFF the Auto Restart Function
Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds but OPERATION lamp does not blink).
How to turn ON the Auto Restart Function
Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).
Note: 1.
In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
2. Default setting of AUTO RESTART OPERATION is ON.
19
Loading ...
Loading ...
Loading ...