OWNER’S MANUAL
R32
AIR CONDITIONER (SPLIT TYPE)
For general public use
1126050202
Indoor unit
RAS-30, 34, 36E2KVG-A
Outdoor unit
RAS-30, 34, 36E2AVG-A

PRECAUTIONS FOR SAFETY
Read the precautions in
this manual carefully before
operating the unit.
This appliance is fi lled with R32.
●
Keep this manual where the operator can easily fi nd it.
●
Read the precautions in this manual carefully before operating the unit.
●
This appliance is intended to be used by expert or trained users in shops, in light
industry and on farms, or for commercial use by lay persons.
●
The precautions described herein are classifi ed as DANGER, WARNING and
CAUTION. They both contain important information regarding safety. Be sure to
observe all precautions without fail.
DANGER
●
Do not install, repair, open or remove the cover. It may expose you to
dangerous voltages. Ask the dealer or the specialist to do this.
●
Turning off the power supply will not prevent potential electric shock.
●
The appliance shall be installed in accordance with national wiring regulation.
●
Means for disconnection from the supply having a contact separation of at least
3 mm in all poles must be incorporated in the fi xed wiring.
●
The appliance must be stored in a room without continuously operating ignition
sources (for example, open fl ames, an operating gas appliance or an operating
electric heater).
●
In order to avoid fi re, explosion or injury, do not operate the unit when harmful
gases (e.g. fl ammable or corrosive) are detected near the unit.
WARNING
●
Do not expose your body directly to cool or warm air for a long time.
●
Do not insert your fi nger or any article into the air inlet/outlet.
●
When an abnormality (burning smell, etc.) occurs, stop the air conditioner and
disconnect the power supply or turn off the breaker.
●
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
●
This appliance is not intended for use by person (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
●
The air conditioner must be installed, maintained, repaired and removed by a
qualifi ed installer or qualifi ed service person. When any of these jobs is to be
done, ask a qualifi ed installer or qualifi ed service person to do them for you.
●
Children should be supervised to ensure that they do not play with the
appliance.

PRECAUTIONS FOR SAFETY
●
Do not use any refrigerant different from the one specifi ed (R32) for
complement or replacement. Otherwise, abnormally high pressure may be
generated in the refrigeration cycle, which may result in a failure or explosion of
the product or an injury to your body.
●
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
●
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open fl ames, an operating gas appliance or an operating
electric heater).
●
Be aware that refrigerants may not contain an odour.
●
Do not pierce or burn as the appliance is pressurized. Do not expose the
appliance to heat, fl ames, sparks, or other sources or ignition. Else, it may
explode and cause injury or death.
CAUTION
●
Do not wash the unit with water. It may cause an electric shock.
●
Do not use this air conditioner for other purposes such as preserving food,
breeding animal, etc.
●
Do not step or put anything on the indoor/outdoor unit. It may cause an injury or
damage the unit.
●
Do not touch aluminium fi n because it may cause an injury.
●
Before cleaning the unit, turn off the main switch or the circuit breaker.
●
When the unit won’t be used for a long time, turn off the main switch or the
circuit breaker.
●
It is recommended that maintenance be performed by a specialist when the unit
has been operated for a long time.
●
The manufacturer shall not assume any liability for the damage caused by not
observing the description of this manual.

Preparing Filters
1. Open the air inlet grille and remove the air filters.
2.
Loading Batteries (when use wireless operation.)
1. Remove the slide cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1. Push
by tip of the pencil.
If timer indication is flashing, go to the next step 2.
2. Press
or : adjust the time.
3. Press
: Set the time.
Remote Control Reset
Push
by tip of the pencil or
1. Remove the batteries.
2. Press
.
3. Insert the batteries.
1
2
3
4
6
5
(
%
&
"
7
!
9
<
=
8
#
)
$
/
-
+
~
,
:
;
.
INDOOR UNIT DISPLAY
1
PREPARATION BEFORE USE
2
AIR FLOW DIRECTION
3
Note:
●
The provided Remote Controller is a wireless type, which also can be
used as a wire. Please see “How to Connect The Remote Controller
for Wired Operation”, located in installation instruction, in case of wired
control is required.
●
In wire operation, remote controller will return to initial condition
(PRESET, TIMER and CLOCK will return to initial condition) when user
shutdown power supply of Air conditioner.
REMOTE CONTROL
4
AUTOMATIC OPERATION
6
To automatically select cooling, heating, or fan only operation
1. Press
02'(
: Select Auto A.
2. Press
: Set the desired temperature. Min. 17°C, Max. 30°C.
3. Press
)$1
: Select AUTO, LOW , LOW+ , MED ,
MED+
, HIGH or Quiet
1. Press
02'(
: Select Cool , Heat , or Fan only .
2. Press
: Set the desired temperature. Min. 17°C, Max. 30°C.
Fan Only: No temperature indication
3. Press
)$1
: Select AUTO, LOW , LOW+ , MED ,
MED+
, HIGH or Quiet
COOLING / HEATING / FAN ONLY
OPERATION
5
DRY OPERATION
7
For dehumidification, a moderate cooling performance is controlled
automatically.
1. Press
02'(
: Select Dry .
2. Press : Set the desired temperature. Min. 17°C, Max. 30°C.
Note: DRY mode fan speed is set to Auto only.
Hi POWER OPERATION
8
To automatically control room temperature and airflow for faster cooling or
heating operation (except in DRY and FAN ONLY mode)
Press
+L32:(5
: Start and stop the operation.
1
Press
),;
: Move the louver
in the desired vertical direction.
2
Press
FIX
: Move the
louver in the desired horizontal
direction.
3
Press
6:,1*
: For select
louver swing operation.
Vertical
(Up-Down)
Swing
Horizontal
(Left-Right)
Swing
Swing off
Up-Down
Left-Right
Swing
Pi Pi
Pi
Pi Pi
●
Vertical (Up-Down) swing
●
Horizontal (Left-Right) swing
Note:
●
Do not move the louver manually by hands or others.
●
The louver may automation positioning by some operation mode.
● Display brightness can be adjusted, follow procedure on .
Require Wireless LAN connecting adapter which available as accessory.
1
ECO (White)
2
Wi-Fi access (White)
3
Hi Power (White)
4
Timer (White)
5
Operation Mode
- Cool (Blue)
- Heat (Orange)
1
Infrared signal emitter
2
Memory and Preset button (PRESET)
3
Start/Stop button
4
Mode select button (MODE)
5
Air fl ow button
6
Fireplace/8°C button
7
ECO button
8
Comfort sleep button (COMFORT SLEEP)
9
Weekly timer (ON/OFF)
!
Temp for Weekly timer
"
On timer button (ON)
#
Set clock button (CLOCK)
$
Check button (CHECK)
%
Filter reset button (FILTER)
&
Temperature button (TEMP)
(
Swing louver button (SWING)
)
Fan speed button (FAN)
~
Set louver Left-Right button (FIX W)
+
Set louver Up-Down button (FIX X)
,
High power button (Hi POWER)
-
Power selection/Silent button (P-SEL/SILENT)
.
Program P1 - P4
/
Day/Edit button
:
Setup button (SET)
;
Off timer button (OFF)
<
Clear button (CLR)
=
Reset button (RESET)
4
Press to select provided air fl ow direction.
Wide
center
Wide right
Spot left
Cancel Air
Flow
Spot right
Spot
center
Wide left
●
Pressing Indoor unit causes “Pi” sound (receiving tone) and
“PiPi” sound when AIR FLOW is canceled.
%
Attach the lters. (see detail in the Installation Manual).

ECO OPERATION
9
COMFORT SLEEP OPERATION
11
To automatically control room temperature to save energy (except in DRY
and FAN ONLY mode)
Press
: Start and stop the operation.
Note : Cooling operation; the set temperture will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
For heating operation the set temperture will decrease.
Fireplace Operation ( )
Keep indoor unit’s fan blowing continuously during thermo off, to circulate heat
from other sources over the room. There are three setting parameters: Default
setting > Fireplace 1 > Fireplace 2
Fireplace 1:
During thermo off period, the indoor unit’s fan will continue to run by the same
speed, previously selected by end-user.
Fireplace 2:
During thermo off period, the indoor unit’s fan will continue to run at super-low
speed, programmed from factory.
8°C Heating Operation (8°C)
Heat mode operation for keep room temperature (5-13°C) with less of energy
usage.
Fireplace and 8°C Heating Operation
8°C
FIREPLACE 1 FIREPLACE 2
Normal
operation
Note:
●
While Fireplace operation on heating mode, indoor unit fan always runs
and cold air breezing might be occurred.
●
Fireplace and 8°C will operate in Heating mode only.
For comfortable sleep, automatically control air fl ow and automatically turn
OFF (Except in DRY mode).
1. Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
2. Press
to cancel the comfort sleep operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
POWER-SELECTION AND SILENT
OPERATION (OUTDOOR UNIT)
12
Power-Selection ( )
This function is used when the circuit breaker is shared with other electrical
appliances. It limits the maximum current and power consumption to 100%,
75%, or 50% and can be implemented by POWER-SELECTION. The lower
percentage, the higher saving and also longer compressor lifetime.
Note:
●
When the level is selected, POWER-SEL level fl ashes on remote LCD
display for 3 seconds.
In case of 75% and 50% level, number “75” or “50” also fl ashes for 2
seconds.
●
Due to the reason that POWER-SELECTION function limits the
maximum current, inadequate cooling or heating capacity may occur.
Silent Operation ( )
Keep outdoor unit operating silently to ensure either yourself or neighborhood
will have a tight sleep in nighttime. By this feature, the heating capacity will
be optimized to deliver such silent experience. The silent operation can be
selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
Though operating silently, the Heating (or Cooling) capacity is still prioritized
to ensure having suffi cient comfort inside the room.
This setting is a perfect balance between the Heating (or Cooling) capacity
and the Sound level of outdoor unit.
Silent 2:
Compromising the Heating (or Cooling) capacity to the Sound level in any
circumstance where the outdoor unit’s sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor
unit by 4 dB(A).
Note:
●
While activating of Silent operation, inadequate heating (or cooling)
capacity may occur.
Power-Selection and Silent Operation (Outdoor Unit)
[100%] [75%] [50%]
SILENT#2 SILENT#1
TIMER OPERATION
13
Set the timer when the air conditioner is operating.
Setting the ON Timer Setting the OFF Timer
1
Press :
Set the desired
ON timer.
Press : Set the desired
OFF timer.
2
Press : Set the timer. Press : Set the timer.
3
Press : Cancel the timer. Press : Cancel the timer.
Note:
●
Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
●
The setting will be saved for the next same operation.
PRESET OPERATION
14
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except airflow direction).
1. Select your preferred operation.
2. Press and hold
for 3 seconds to memorize the setting.
The P mark displays.
3. Press
: Operate the preset operation.
FIREPLACE AND 8°C HEATING
OPERATION
10

DISPLAY LAMP BRIGHTNESS ADJUSTMENT
15
To decrease the display lamp brightness or turn it off.
1. Press and hold
)$1
for 3 seconds until brightness level ( , ,
or ) is shown on remote control LCD then release the button.
2. Press
Rise
or
Decrease
to adjust brightness in 4 levels.
Remote control
LCD
Operation display Brightness
Lamp illuminates full brightness.
100%
Lamp illuminates 50% brightness.
50%
Lamp illuminates 50% brightness and the
operation lamp is turned off.
50%
All lamps are turned off.
All turned off
●
In the examples of
and , the lamp illuminates for 5 seconds before
going off.
16
SELF CLEANING OPERATION
(COOL AND DRY OPERATION ONLY)
17
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
more 2 times
within 30 seconds.
TEMPORARY OPERATION
18
In case of the misplaced or discharged remote control
●
Pressing the RESET button, the unit can start or
stop without using the remote control.
●
Operation mode is set on AUTOMATIC operation,
preset temperature is 24°C and fan operation is
automatic speed.
REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the
pencil. “00” will be shown on the display. (Picture 1)
4. Press
02'(
during pushing . “B” will show on the display and
“00” will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized. (Picture 2)
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
OPERATION AND PERFORMANCE
20
1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating
operation starts.
3. Warm air control: When the room temperature reaches the set
temperature, the fan speed is automatically reduced and the outdoor unit
will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into
the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit
where it will not be subjected to snow drifts, accumulation of leaves or
other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is normal
because the cracking sound may be caused by expansion/contraction of
plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature Room Temperature
Heating –15°C ~ 24°C Less than 28°C
Cooling –10°C ~ 46°C 21°C ~ 32°C
Dry –10°C ~ 46°C 17°C ~ 32°C
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
●
Clean the indoor unit and the remote control with a wet cloth when
needed.
●
No benzine, thinner, polishing powder or chemically-treated duster.
Air filters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air filters.
3. Vacuum or wash and then dry them.
4. Reinstall the air filters and close the air inlet grille.
MAINTENANCE
21
1
2
The unit does not operate.
Cooling or Heating is abnormally low.
●
The power main switch is
turned off.
●
The circuit breaker is activated
to cut off the power supply.
●
Stoppage of electric current
●
ON timer is set.
●
The fi lters are blocked with dust.
●
The temperature has been set
improperly.
●
The windows or doors are opened.
●
The air inlet or outlet of the outdoor
unit is blocked.
●
The fan speed is too low.
●
The operation mode is FAN or DRY.
●
POWER SELECTION function is
set 75% or 50% (This function is
depend on remote controller).
TROUBLESHOOTING (CHECK POINT)
22
AUTO RESTART FUNCTION SETTING
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
Information
The product is shipped with Auto Restart function in the ON position.
Turn it OFF if this function is not required.
How to turn OFF the Auto Restart Function
●
Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds but OPERATION lamp does not blink).
How to turn ON the Auto Restart Function
●
Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).
Note: 1.
In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
2. Default setting of AUTO RESTART OPERATION is ON.
19

How to set WEEKLY TIMER
1. Press to enter WEEKLY TIMER setting.
2. Press to select desired day in sequence.
The sequence of day symbol appears on the LCD.
SU t MO t TU t WE t TH t FR t SA
WEEKLY SUMO
TUWETHFRSA
(All day)
3. Press to select the program number.
●
The program 1 is ready for setting while is
pressed PG-1 appears on the LCD.
●
Press
to change the program number in
the sequence program 1 to program 4.
PG-1
PG- 2
PG- 3
PG- 4
4. Press or to select the desired time.
●
The time can be set between 0:00 and 23:50 in
10 minute intervals.
●
Press and hold the button to change setting time
for 1 hr.
●
Only one of ON or OFF timer can be set on each
program.
ON timer display OFF timer display*
* OFF timer is used to stop the air conditioner only.
The display does not show Operation mode,
Temperature, Fan speed and others.
5. Press to select desired operation.
6. Press or to select desired temperature.
●
The temperature can be set between 17°C and
30°C.
7. Press
to select the desired fan speed.
8. Add operations, if required.
●
Press to use 8°C operation.
(Notes: Fireplace cannot select and memorize in
weekly function)
●
Press to use ECO operation.
●
Press
to use Hi POWER operation.
●
Press
to use Silent operation.
9. Adding or editing the program.
The program can be set to perform on all the required
days until is pressed to confi rm the setting.
10. If adding or editing a program is required, please
repeat steps 2 - 8 before setting confi rmation.
11. After adding or editing, press
to confi rm the
setting*.
Operating Mode
Weekly timer running
Next program
Timer ON or OFF
Next operation
time
Operating Temperature
and Fan speed
Display after
pressing SET
button
WEEKLY TIMER OPERATION
23
Blink
*Point remote control at air conditioner receiving
module then, press SET button until you hear the
“PiPi” sound. This means the setting operation has
been completed. As the air conditioner is receiving
the signal, you will hear separate “Pi” sounds
corresponding to the number of days in the selected
setting.
An incomplete setting is indicated if the TIMER lamp
is blinking. Press
twice.
Notes :
1. Place the remote control where the indoor unit can receive the signal.
This will increase the accuracy of the timing between the remote control
and the air conditioning unit.
2. The ON/OFF timer can be set during the WEEKLY TIMER operation. In
this situation, the air conditioner will fi rst follow the normal timer until it is
complete; then, it will return to the WEEKLY TIMER function.
3. During WEEKLY TIMER operation, all of operation such as MODE, TEMP,
FAN, Hi POWER, ECO and etc., can be adjusted but when the clock
reaches the program setting, the operation will return to the set items in
the program.
4. When the remote control is sending a signal to the air conditioner, avoid
interference from objects that can block the signal.
Edit Weekly timer program
To edit the program after confi rming the weekly timer
setting, follow steps 1 - 3 below.
1. Press
.
●
The day of the week and the program number of
the current day will be displayed.
2. Press
to select the day of the week and
press
to select program number to be
confi rmed.
●
Resetting the operation.
3. Press
to exit confi rming mode.
Deactivating WEEKLY TIMER operation
Press
while “WEEKLY” is displayed on the
LCD.
●
The “WEEKLY” indicator will disappear from the
LCD. However, the program will remain in the
remote control.
●
The TIMER lamp goes off.
●
To reactivate the WEEKLY TIMER operation again,
press again, LCD shows the next program.
The program, after reactivation, is related to the
clock time.
To delete programs
The individual program
1. Press
.
●
The day of the week and the program number
is displayed.
●
Select the day to delete the program.
2. Press
to select the program number to be
deleted.
3. Press
.
●
ON or OFF timer will be cleared and the LCD
will blink.
4. Press to delete the program.
●
Press
while the LCD is blinking.
The program has now been deleted.
All programs
1. Press
.
●
The day of the week and the program number
will be displayed.
2. Press
and hold for 3 seconds.
●
All programs will be deleted and LCD displays
current operation.
Notes :
Make sure the remote control receiving module
on the air conditioner receives the signal from the
remote control.





1126050202