Ancona AN1251 30 Inch Stainless Steel Convertible Standard Hood Under Cabinet Hood

User Manual - Page 21

For AN1251.

PDF File Manual, 24 pages, Read Online | Download pdf file

AN1251 photo
Loading ...
Loading ...
Loading ...
— 21 —
Problem Possible Cause
If the range hood or LED light
does not operate after installation:
Check if the range hood has been plugged in, make sure that all power
has been turned back ON, fused not blown and all electrical wiring are
properly connected.
The range hood vibrates when the
blower is on:
The range hood might not have been secured properly on to the ceiling or
wall.
The blower or fan seems weak: Checkthattheductsizedusedisatleast6in.(15.3cm)or31/4x10in.
(8.3 x 25.4 cm). Range hood WILL NOT function efciently with insufcient
ductsize.Forexample:7in.(17.7cm)ductover6in.(15.3cm)holeand
loosely secured.
Checkifductiscloggedorifdamperunit(half-circularange)isnot
installed correctly or opening properly. A tight mesh on a side wall cap unit
mightalsocauserestrictiontotheairow.
The lights work but the fan is not
spinning at all, is stuck or is rattling:
The fan might be jammed or scraping the bottom due to shipping damage.
Please contact us immediately.
The hood is not venting out
properly:
Make sure the distance between the stove top and the bottom of the hood
is within 24 in. and 30 in. (61 and 76.2 cm) in distance.
Reduce the number of elbows and length of duct work. Check if all joints
are properly connected, sealed, and taped.
Troubleshooting
Loading ...
Loading ...