18 English
Adjust the flow rate with the +/- button.
The support plate is blocked.
Clean the support plate.
Customer Service department
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.
Warranty
The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
Technical data
IVR-L 100/
24-2
IVR-L 100/
24-2 Tc
IVR-L 120/
24-2 Tc
Electrical connection
Mains voltage V 220-240 220-240 220-240
Phase ~111
Power frequency Hz 50-60 50-60 50-60
Degree of protection IPX4 IPX4 IPX4
Protection class I I I
Nominal power W 2400 2400 2400
Power protection (slow-blowing) A 16 16 16
Dimensions and weights
Typical operating weight standard
(Me)
kg 44 47 66
Typical operating weight Dp (Me) kg 57 76
Length x width x height mm 825 x 660 x
1210
840 x 660 x
1320
810 x 720 x
1595
Ambient conditions
Ambient temperature °C +40 +40 +40
Device performance data
Tank content l 100 100 120
Air quantity l/s 2 x 74 2 x 74 2 x 74
Vacuum kPa
(mbar)
23 (230) 23 (230) 23 (230)
Nominal width of the suction hose DN50 DN50 DN50
Determined values in acc. with EN 60335-2-69
Hand-arm vibration value m/s
2
< 2.5 < 2.5 < 2.5
Uncertainty K m/s
2
0.2 0.2 0.2
Sound pressure level L
pA
dB(A)686868
Uncertainty K
pA
dB(A)222
Loading ...