Karcher 9.987-885.0 Industrial vacuum IVR-L 100/24-2 Tc

Bedienungsanleitung - Page 15

For 9.987-885.0.

PDF File Manual, 194 pages, Read Online | Download pdf file

9.987-885.0 photo
Loading ...
Loading ...
Loading ...
English 15
ATTENTION
Risk of damage to the device
Leaking water due to the maximum fluid
level being exceeded.
Drain the device before the maximum fluid
level is reached.
Device description
See graphics page for illustrations
Illustration A
1 Steering rollers with parking brake
2 Maximum filling level mark
3 Drain hose
4 Liquid container
5 Push handle
6 Deflector plate
7 Screw plug
8 Filter
9 Suction head
10 Drum pump on/off switch
11 Drum pump flow rate adjustment (+/-
button)
12 Drum pump
13 Drum pump disposal hose
14 Suction hose connection
15 Power switch
16 Suction head lock
17 Mains cable
18 Disposal hose holder
19 Unlocking lever
20 Stand pipe for drum pump
21 Tilting chassis
22 Liquid container crane grommet
23 Accessory holder
Start-up
See graphics page for illustrations
1. Bring the device into the working posi-
tion.
2. If necessary, secure the device using the
parking brake.
3. Ensure that the suction head is fitted
correctly.
4. Insert the suction hose into the suction
hose connection.
Illustration B
5. Plug the desired accessory onto the suc-
tion hose.
Operation
See graphics page for illustrations
1. Plug the mains plug into the socket.
2. Switch on the device using the power
switch.
Illustration C
The switch has multiple level settings:
0The device is off.
1Motor 1 is switched on.
2Motors 1 and 2 are switched on.
3. Start vacuuming.
Suction process
Note
Only immerse the accessory halfway when
vacuuming liquids to encourage sufficient
air.
Checking the filling level display
See graphics pages for illustration
Illustration D
Note
The red marking on the drain hose shows
the maximum permissible filling level.
ATTENTION
Risk of damage to the device
The liquid container will overflow within a
few seconds of filling.
Constantly check the filling level in the liq-
uid container when filling large quantities of
liquid.
Emptying the liquid container
See graphics page for illustration
1. Switch the device off and disconnect it
from the power supply.
2. Move the device to the waste water tank.
3. Empty the liquid container:
a Connect the drain hose to the upper
hose coupling.
Illustration E
b Hold the drain hose over a suitable
collecting container and drain the con-
tents.
Loading ...
Loading ...
Loading ...