GP[1]8910E Electric Griddle Range, Static Oven 900 mm wide.
GP[1]8910EC Electric Griddle Range, Convection Oven 900 mm wide.
NOTE:
[1]: - Model Options;
- - Standard.
L - Low Back.
B - Bold Front.
LB - Low Back and Bold Front.
A commercial heavy duty, 900mm wide, Electric Griddle Range, designed for modular kitchens and
constructed in an easy clean stainless steel external finish. The griddle elements are constructed
using stainless steel sheathed heating elements with dual thermostatic control zones.
The Griddle uses a 20mm thick griddle plate with the option of either ribbed or chromed mirror plate
options.
The range can be equipped with either an electric 6.5kW convection or static oven, 900mm wide.
Electrical supply connection point is located at the rear of the appliance, approximately 80 mm from
the right hand side and 467 mm from the rear and 150 mm from the floor.
When connecting a Waldorf electric appliance to the main supply, ensure that the following is carried
out:-
An isolating switch is fitted within 2 m of the appliance, but not on the appliance and in
such a position that the user does not have to reach across the cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS
3191 part 2.10.11. or IEC 60245-IEC-57) e.g. H05 RN-F Type.
The branch supply line shall be individually overload protected to the correct current rating
and the supply chord shall be protected against any mechanical or thermal damage.
A grommet is fitted around the wiring entry hole into the appliance.
All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance
for the current drawn on that line.
MODEL
Fan Motor
3-Phase Connection
3P+N+E
400-415V, 50/60Hz
GP8910E 18.5 kW
L1 - 24.6 Amps
L2 - 25.6 Amps
L3 - 25.6 Amps
---------
GP8910EC 18.9 kW
L1 - 25.9 Amps
L2 - 25.6 Amps
L3 - 25.6 Amps
100W
THIS APPLIANCE MUST BE EARTHED. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY