Blue Seal Evolution G518D-CB Series 1200mm Gas Cooktop Cabinet Base

Installation Operation Manual - Page 15

For G518D-CB.

PDF File Manual, 30 pages, Read Online | Download pdf file

G518D-CB photo
Loading ...
Loading ...
Loading ...
13
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.
1. Blue Seal Cooktops do not require electrical connection, as they function totally on the gas supply.
2. It is essential that gas supply is correct for Cooktop being installed and that adequate supply
pressure and volume are available. The following checks should be made before installation:-
a. Gas Type the appliance has been supplied for is shown on a coloured stickers located above gas
entry point and on rating plate. Check that this is correct for gas supply the appliance is being
installed for. Gas conversion procedure is detailed in this manual.
b. Supply Pressure required for this appliance is shown in Specifications section of this manual.
Check gas supply to ensure that adequate supply pressure exists.
c. Input Rate of this appliance is shown on Rating Plate and in Specifications section of this
manual. Input rate should be checked against available gas supply line capacity. Particular note
should be taken if appliance is being added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to the connection joint on appliance
with as few tees and elbows as possible, to give maximum supply volume.
3. Fit gas regulator supplied, into gas supply line as close to appliance as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as per Gas Conversion Sectionin this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and it
is NOT to be adjusted.
For G512C-B and G512D-B models, regulator connection is ½" BSP female. Connection on
unit is ½" BSP male.
For G514 / G516 / G518, regulator connections are ¾" BSP female. Connection on unit is ¾"
BSP male.
(Refer to the Specificationssection for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
4. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
the appliance is level and at correct height.
5. Connect gas supply to appliance. A suitable joining compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
6. Check all gas connections for leakages using soapy water or other gas detecting equipment.
7. Check that gas operating pressure is as shown in Specificationssection.
NOTE: Operating pressure to be measured at
manifold test point and with 2 burners
operating at High Flamesetting.
8. Verify operating pressure remains correct.
Manifold
Test Point
Fig 2
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
Loading ...
Loading ...
Loading ...