Smeg PGA31G-1 Hob Stainless steel

User manual EN pdf - Page 22

For PGA31G-1.

PDF File Manual, 24 pages, Read Online | Download pdf file

PGA31G-1 photo
Loading ...
Loading ...
Loading ...
Installation
24
Burner and nozzle characteristics tables
The nozzles not provided are available at Authorised Service Centres.
5.6 Electrical connection
General information
Check the mains characteristics against the
data indicated on the plate.
The identification plate bearing the
technical data, serial number and brand
name is visibly positioned on the appliance.
Do not remove this plate for any reason.
Perform the ground connection using a wire
that is 20 mm longer than the other wires.
The appliance can work in the following
modes:
220-240 V 1N~
Use a 3 x 0.75 mm² three-core cable.
NG 1.0 kPa AUX RR UR2 int. UR2 ext.
Rated heating capacity (MJ/h)
3.9 9.0 3.6 14.4
Nozzle diameter (1/100 mm)
0.9 1.4 0.9 1.75
ULPG 2.75 kPa AUX RR UR int. UR2 ext
Rated heating capacity (MJ/h)
3.9 9.0 3.6 13.4
Nozzle diameter (1/100 mm)
0.54 0.85 0.5 1.00
Power voltage
Danger of electrocution
• Have the electrical connection
performed by authorised technical
personnel.
• Use personal protective equipment.
• The appliance must be connected to
ground in compliance with electrical
system safety standards.
• Disconnect the mains power supply.
• Do not pull the cable to unplug the
appliance.
• Use cables withstanding a temperature
of at least 90°C.
• The tightening torque of the screws of
the terminal board leads must be 1.5 -
2 Nm.
Pass the power supply cable
through the back of the unit, taking
care that it does not touch the
bottom casing of the hob or the
oven (if any) installed underneath
it.
The values indicated above refer
to the cross-section of the internal
lead.
Loading ...