Smeg PM6954R Mixed Hob 90 cm

User manual - Page 26

For PM6954R.

PDF File Manual, 28 pages, Read Online | Download pdf file

PM6954R photo
Loading ...
Loading ...
Loading ...
58 - INSTALLATION 91477A185/D
regulations.
For the Australian/New Zealand market:
The circuit breaker incorporated in the fixed
connection must comply with AS/NZS 3000.
Power limitation procedure
In order to modify the maximum power
absorbed by the appliance, you have to access
the user menu (see “User menu”). The power
limitation option, as well as the first that is
proposed, is marked with the code .
The front and rear right zone displays indicate
the numbers associated with the factory set
power (expressed in kW):
(7.4 kW). Use the scroll bar on the right
to modify the power: press the left part to
decrease it and the right part to increase it.
The Eco-Logic Advance function increases or
decreases the power level in steps of 0.1 kW at
each touch.
To exit from the user menu, see the “User menu”
chapter.
Section cut from the countertop
Safety instructions for positioning and
installation
Installation can be carried out on various
materials such as masonry, metal, solid
wood or plastic laminated wood as long as
they are heat resistant (>90°C).
Veneers, adhesives or plastic coatings on
adjacent furniture should be temperature-
resistant (>90°C), otherwise they might
warp over time.
If the piece of furniture does not have the
required recess opening, either it will have
to be cut or masonry work carried out by a
competent technician.
The minimum clearance between exhaust
hoods and the cooking surface must be at
least the distance indicated in the exhaust
hood installation instructions.
The minimum clearances must also be
respected for the edges of the hob on the
back as indicated in the assembly
instructions.
If the appliance is to be installed above an
oven, the oven must be fitted with a cooling
fan.
Appliance overall dimensions (mm)
Built-in cabinet dimensions (mm)
Hob seal
To prevent leakage of liquid between the frame
of the hob and the countertop, place the
adhesive seal provided along the entire outer
This procedure is restricted to the
installer.
The appliance is factory set to
maximum power.
See General safety instructions.
L
Models A 35 cm 350
Models B 65 cm 650
Models C 90 cm 900
A min. 200
B min. 460
C min. 750
D 40 - 60
Emin. 50
L
min. 650 - models A 65 cm
min. 750 - models B 75 cm
min. 900 - models C 90 cm
Loading ...