Cleaning
4) Remove the front insulation panel, then remove
splash guard, cube guide B, and cube guide A.
See Fig. 16. Next, remove the overow cap,
overow pipe, water shield, and drain plug.
After the water tank has drained, replace the drain
plug, water shield, overow pipe, overow cap,
cube guide A, cube guide B, splash guard, and
front insulation panel.
NOTICE! Be careful not to cross thread the
drain plug and overow pipe.
5) To ll the water tank, move the control
switch to the "ICE" position, then replace
the front panel. After 3 min., remove the
front panel, then move the control switch to
the "OFF" position.
6) Remove the front insulation panel, then pour 14 . oz. (414 ml) of Hoshizaki "Scale
Away" into the water tank. Replace the front insulation panel. Turn the cleaning valve to
the left until completely vertical (open).
7) NOTICE! To avoid excessive foaming, wait 1min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front
panel.
8) After 30 min., remove the front panel, then move the control switch to the "OFF"
position.
9) Remove the front insulation panel, then remove splash guard, cube guide B, and cube
guide A.
Remove the overow cap, overow pipe, water shield, and drain plug. After the water
tank has drained, replace the drain plug, water shield, overow pipe, overow cap, cube
guide A, cube guide B, splash guard, and front insulation panel.
10) In bad or severe water conditions, turn off the power supply, then remove, clean
(cleaning solution = 5 oz. Hoshizaki "Scale Away" per gallon of warm water), rinse, and
replace the splash guard, cube guides, oat switch, water supply tubes, spray tubes,
and spray guides; turn on the power supply when complete. Otherwise, continue to
step 11.
Cleaning Rinse
11) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position, then replace the front panel. After 3 min., remove the front
panel, then move the control switch to the "OFF" position. Note: The icemaker will not
operate unless the cleaning valve is completely closed.
12) Turn the cleaning valve to the left until completely vertical (open). Move the control
switch to the "WASH" position, then replace the front panel. After 5 min., remove the
front panel, then move the control switch to the "OFF" position.