I. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
NOTICE
• If the appliance is turned off, wait for at least 3 minutes before restarting the
appliance to prevent damage to the compressor.
To prevent damage to the water pump seal, do not leave the control switch in the
"WASH" position for extended periods when the water tank is empty.
At startup, conrm that all internal and external connections are free of leaks.
Additional Notice for Remote Models
The appliance must have power for a minimum of 4hours prior to startup to
prevent compressor damage.
1) Open the water supply line shut-off valve(s).
2) Remove the front panel.
3) Move the control switch on the control box to the "ICE" position.
4) Replace the front panel in its correct position.
5) Turn on the power supply, and allow the appliance to operate for a total of 10 minutes.
6) Turn off the power supply, then remove the front panel.
7) Remove the insulation panel, then remove
splash guard, cube guide B, and cube
guide A. Next, remove the overow cap,
overow pipe, water shield, and drain plug.
See Fig. 15.
8) After the water tank has drained, replace
all parts removed in step 7 in their correct
positions. Be careful not to cross thread the
drain plug or overow pipe.
9) Clean the dispenser unit/ice storage
bin liner using a neutral cleaner. Rinse
thoroughly after cleaning.
10) Replace the front panel in its correct
position.
11) Turn on the power supply to start the automatic icemaking process.
12) During the rst 5 minutes of the freeze cycle, conrm bin control operation by pressing
and holding the bin control's actuator paddle until the appliance shuts down. The
appliance should shut down in approximately 15 seconds.
13) On water-cooled models, conrm proper condenser drain outlet/return outlet
temperature as outlined in "II.F.2. Water-Cooled Condenser."