6.2.15 Encoder
Description
This tab displays all the encoders that have been detected, and also shows the detailed data and related settings
of each encoder.
<Remark> If there is no available image source, the Image button will be red. Gray N/A means that the function
is not supported.
No
Item
Function Descriptions
1
Remove
It can remove unconnected encoder (marked ).
2
Hello
After clicking, the LED indicator on the front panel of the encoder flashes immediately,
making it easier to find the encoder. Click this button again to restore the normal
operation of the LED indicator.
3
Icon
Show the icon that represents the encoder. for connected; for unconnected.
4
Order
It can select the order of each encoder.
5
Name
Show the name of the encoder. Click Device > [Settings] to enter 12 letters or numbers
to change its name.
6
IP address
Show the IP address of the current encoder.
7
Video
Display the detailed information of the image input source.
<Remark> If there is no image source, the button is red.
8
Network
Click the [Settings] button to display detailed network information. The default mode is
Auto IP.
9
RS-232
Show the detailed information of the current RS-232 serial.
10
Device
Show the detailed information of the device. For detailed settings, please see 6.2.16
Encoder - Device Settings.
11
USB
Show the detailed information of the current USB, and the settings can be changed here.
The default is Auto Select mode. K/M Over IP and USB HID URB interval: A special
optimization function can be used to solve the abnormal response of the mouse or touch
screen. You can choose to enable or disable it. The default setting is disabled.