About the controls on the air conditioner
Vent Control
Theventcontrol islocatedbehindthe frontgrilleon the
right sideofthe air dischargearea.WhenCLOSED,only
the air insidethe roomwill becirculatedand conditioned.
WhenOPEN,the ventallowsoutdoorfresh air exchange.
Toopenor closethe vent:
1. Removethefront grille.
2. Removetheventcard screw.
3. Removeventcard,turn it overand replaceit by
locatingrearholein cardoverlocatingpininsideair
dischargeandreattachingscrewat front.
Theunitleavesthefactorysetat the CLOSEposition.
ocatinghole
OPENposition
(Meshendtowardback)
hole
Screwhel
CLOSEposition
(Meshendtowardfront)
Air Direction
Horizontallouvers
onthefront grille
letyou controlthe
airdirectionupand
down.
Cool Only Models
Auxiliary Controls - Dip Switches (location varies by model)
The auxiliary dip switch controls are located
behind the room cabinet-as shown in this figure.
The owner is responsiblefor checking switches
and ensuring they are in the desired position.
front grille
tjustthe vertical
louversside-to-side
the airleft
ght.
- Cool
(reserved
forfuture use)
Fan Cycle/Continuous - Cool
When this switch is enabled (RIGHT),it allows the indoor
fan to cycle on/off with the compressor. When this
switch is disabled (LEFT),it allows the indoor fan to run
continuously. The default setting is left (continuous).
FanCycle/Continuous-Cool
Heat/Cool Models
Auxiliary Controls - Dip Switches (location varies by model)
The auxiliary dip switch controls are located
behind the room cabinet-as shown in this figure.
The owner is responsiblefor checking switches
and ensuring they are in the desired position.
FanCycle/Continuous- Cool
FanCycle/Continuous- Heat
,t__ Class 2
m Nofunction(reserved
UP forfutureuse)
DOWN