Tripp Lite U280-001-W2-HG 1-Port Isolator Hospital-Grade USB Wall Charger, UL 60601-1 for Patient Care Areas, USB-A, 2.5A

Healthcare/Medical Solutions - Page 2

For U280-001-W2-HG.

PDF File Manual, 6 pages, Read Online | Download pdf file

U280-001-W2-HG photo
Loading ...
Medical-grade UPS systems provide medical-grade
regulatory compliance for connected equipment. All
models include built-in Faraday shielding that provides full
line isolation and reduces the cumulative leakage current
of connected equipment to less than 100 μA for optimal
safety in patient care vicinities. Full isolation also provides
continuous noise filtering and enhanced common mode
surge protection.
In addition to full isolation, medical-grade UPS systems
provide battery backup during blackouts, allowing
connected equipment to continue operating without
interruption. UPS systems also improve generator backup
by supporting equipment during the lag between power
outages and generator startup. UPS systems automatically
switch between utility power and battery backup in 2 to
5 ms, which is well within the fault tolerances of sensitive
computer equipment. Automatic voltage regulation
(AVR) keeps equipment working through voltage sags
(brownouts) or high voltages indefinitely, without draining
battery power. All models protect connected equipment
against damaging surges and disruptive EMI/RFI line
noise. SMART2500XLHG also provides pure sine wave
output from battery.
Models SMART700HGL, SMART1200XLHGL, SMX700HGL
and SMX1200XLHGL include a Lithium Iron Phosphate
(LiFePO
4
) battery with a 10,000-cycle life (20-30 times the
cycle life of traditional batteries) and a 5-year warranty.
Medical-Grade UPS Systems
UL/IEC 60601-1 and
UL 1778 Compliant
Approved for Use in
Patient Care Vicinities
Reduce Cumulative Shock Potential
to Less than 100 µA (Full Isolation)
Lead Acid & Lithium Battery Technology
SMX1200XLHG UPS System (back)
SMART1200XLHG UPS System (back)
Model
Output
Capacity
Nominal AC
Voltage UL/IEC Compliance
Typical Backup Runtime
(Half/Full Load)
(1)
Hospital‑Grade
AC Outlets
Communication
Ports
(2)
AC Input
Cord Length
AC Input Plug
or Inlet
Medical‑Grade UPS Systems (For use inside and outside patient care vicinities.)
SMART2500XLHG
2,200VA/1,920W 120 V UL 60601-1 and 1778 13/4.4 min. + 4 (5-15/20R HG), 4 (C13) Serial, USB, EPO 6 ft.
(3)
5-20P/C20
(3)
SMART1200XLHG
1,000VA/750W 120 V UL 60601-1 and 1778 28/10 min. + 4 (5-15R HG) Serial and USB 6 ft. 5-15P HG
SMART1200XLHGL
(4)
1,000VA/750W 120 V UL 60601-1 and 1778 28/10 min. + 4 (5-15R HG) Serial and USB 6 ft. 5-15P HG
SMART700HG
700VA/450W 120 V UL 60601-1 and 1778 42/18 min. 4 (5-15R HG) Serial and USB 6 ft. 5-15P HG
SMART700HGL
(4)
700VA/450W 120 V UL 60601-1 and 1778 42/18 min. 4 (5-15R HG) Serial and USB 6 ft. 5-15P HG
OMNISMART350HG
330VA/225W 120 V UL 60601-1 and 1778 46/18 min. 4 (5-15R HG) Serial 6 ft. 5-15P HG
SMX1200XLHG
1,000VA/750W 230 V IEC 60601-1 27.5/11 min. + 6 (C13) Serial and USB 6 in. C14
(5)
SMX1200XLHGL
(4)
1,000VA/750W 230 V IEC 60601-1 28/10 min. + 6 (C13) Serial and USB 6 in. C14
(5)
SMX700HG
700VA/450W 230 V IEC 60601-1 36/14.5 min. 6 (C13) Serial and USB 6 in. C14
(5)
SMX700HGL
(4)
700VA/450W 230 V IEC 60601-1 42/18 min. 6 (C13) Serial and USB 6 in. C14
(5)
OMNIX350HG
350VA/225W 230 V IEC 60601-1 37/15.5 min. 6 (C13) USB 6 in. C14
(5)
Certifications vary by model. Go to www.tripplite.com for more information, including weights, dimensions and updates. (1) Backup runtimes vary with load, battery condition and other factors. Increase runtimes for “+” models by connecting
optional external battery packs. Refer to www.tripplite.com for compatible battery packs. (2) Serial ports are RS-232/DB9. USB and serial ports work with PowerAlert software (free download) or compatible third-party software. SMART2500XLHG
has an accessory slot that supports Tripp Lite’s optional network management card that provides a network interface for remote management via SNMP, Web, SSH or telnet. (3) Detachable 6 ft. AC input cord with 5-20P plug connects to C20 inlet
with locking clamp. (4) Includes Lithium Iron Phosphate (LiFePO4) battery with 20-30 times the cycle life of traditional batteries. (5) Connects to a user-supplied AC input cord and plug compatible with the facility’s wall outlets.
APPROVED FOR PATIENT CARE VICINITIES
Medical-Grade Power for Mobile Carts and Telemedicine
UL/IEC 60601-1 and
UL 1778 Compliant
Approved for Use in
Patient Care Vicinities
Reduce Cumulative Shock Potential
to Less than 100 µA (Full Isolation)
Mobile power retrofit kits provide the inverter/charger and controller in one mobile power solution. The user can upgrade new
or existing mobile medical carts for a fraction of the cost of buying new powered carts, providing medical-grade compliance for
connected equipment. They can also be used as telemedicine power systems.
The user-replaceable battery provides up to 12 hours of mobile power. When the power module is plugged into a wall outlet, it
quickly recharges the battery for faster cart rotation between shifts. Included PowerAlert
®
software prevents computer data loss
if battery power runs out before recharging. The retrofit kit is compatible with most popular carts by AFC, Anthro, Datalux, GCX,
Hergo, Jaco, Knurr, Stinger and others.
HCRK /
HCRK-54 / HCRK-36
Power Module
Add
AC Power
to Mobile
Medical
Carts
Model Nominal AC Voltage Wattage UL/IEC Compliance Battery Capacity Typical Runtime
(1)
AC Outlets Comm. Port AC Input Cord Length AC Input Inlet
MedicalGrade Mobile Power Retrofit Kits (For use inside and outside patient care vicinities.)
HCRK
120 V 300W UL 60601-1 and 1778 90 Ah Up to 12 hours 3 (5-15R) USB 1 to 10 ft. (Coiled Cord) 5-15P HG
HCRK54
120 V 300W UL 60601-1 and 1778 54 Ah Up to 6 hours 3 (5-15R) USB 1 to 10 ft. (Coiled Cord) 5-15P HG
HCRK36
120 V 300W UL 60601-1 and 1778 36 Ah Up to 4 hours 3 (5-15R) USB 1 to 10 ft. (Coiled Cord) 5-15P HG
HCRKINT
230 V 300W IEC 60601-1 90 Ah Up to 12 hours 1 (C13) USB 8 in. C14
(2)
Certifications vary by model. Go to www.tripplite.com for more information, including weights, dimensions and updates. (1) Typical runtime between charges for common mobile medical cart applications. Runtimes vary with equipment
load, charge level, battery condition and other factors. (2) Connects to a user-supplied AC input cord and plug compatible with the facility’s wall outlets.
Medical-Grade Power Strips
UL 60601-1 and 60950-1
or 1363A Compliant
Approved for Use in Patient Care Vicinities
Reduce Shock Potential of
Connected Equipment
Provide Power Distribution
Include Hospital-Grade Plug and Outlets
Antimicrobial Protection
Tripp Lite’s HGULTRA Series UL 60601-1 compliant power
strips provide safe, convenient AC power in a durable metal
housing, ideal for use anywhere outlets and space are limited.
Multiple hospital-grade outlets permit operation of additional
equipment in locations that do not have additional wall outlets
available, including inside patient care vicinities.
A patented protection circuit guards against shock hazards
by preventing power from reaching the unit’s outlets in the
presence of a fault. This protection circuit automatically resets
itself and restores power once the fault threat is gone. With a
switchless design that prevents accidental shutoff, built-in outlet
safety covers and a 6 ft. or 15 ft. power cord, HGULTRA Series
power strips are the perfect replacements for all non-compliant
power strips.
Tripp Lite’s OEM Series power strips are designed to be
permanently mounted to carts, IV poles, racks, tables, pedestals
and similar equipment in order to supply power to the plug-
connected components of movable medical equipment
assemblies. Equipped with long power cords and multiple
hospital-grade outlets, OEM-series power strips provide
versatile power distribution inside and outside patient care
vicinities.
To promote patient and staff safety, Tripp Lite’s medical-grade
power strips have a patented antimicrobial coating to help
reduce the risk of healthcare-acquired infections.
Model Nominal AC Voltage UL Compliance Surge Protection Rating HospitalGrade AC Outlets AC Input Cord Length AC Input Plug Type
MedicalGrade Power Strips (For use inside and outside patient care vicinities.)
PS406HGULTRA
120 V UL 60601-1 and 60950-1 4 (5-15R HG)
(1)
6 ft. 5-15P HG
PS415HGULTRA
120 V UL 60601-1 and 60950-1 4 (5-15R HG)
(1)
15 ft. 5-15P HG
SPS415HGULTRA
120 V UL 60601-1 and 60950-1 1,410 joules 4 (5-15R HG)
(1)
15 ft. 5-15P HG
OEMSeries MedicalGrade Power Strips (For use inside and outside patient care vicinities. Must be permanently mounted inside patient care vicinities.)
PS607HGOEM
120 V UL 1363A 6 (5-15R HG)
(1)
7 ft. 5-15P HG
PS615HGOEM
120 V UL 1363A 6 (5-15R HG)
(1)
15 ft. 5-15P HG
PS415HGOEM
120 V UL 1363A 4 (5-15R HG) 15 ft. 5-15P HG
PS410HGOEMCC
120 V UL 1363A 4 (5-15R HG)
(2)
3 to 10 ft. (Coiled Cord) 5-15P HG
PS410HGOEMX
(3)
120 V UL 1363A 4 (5-15R HG) 10 ft. 5-15P HG
Accessories (For use inside and outside patient care vicinities.)
HGOUTLETCVR
Pack of 4 reusable, self-locking HG outlet safety covers. Covers block outlet access and require a tool to remove, meeting code requirements.
PSHGCOVERKIT
Replacement duplex outlet covers for Tripp Lite medical-grade power strips and surge protectors. Includes 6 replacement covers and attachment hardware.
PSCLAMP
Power strip mounting clamp for IV poles, beds, carts, etc. Adjusts to fit diameters from 1 to 2.25 in. Includes cord manager and removable drip shield.
Certifications vary by model. Go to www.tripplite.com for more information, including weights, dimensions and updates. (1) Includes integrated safety covers. (2) Includes 4 reusable, self-locking HG outlet safety covers. (3) Includes built-in cord
manager and removable drip shield.
UL 60601-1,
1778
Certified
by:
UL 60601-1
UL 1778
PSHGCOVERKIT
Certified
by:
*
Regulates the use of electrical
and IT equipment in medical
environments.
UL 60601-1
UL 60950-1
*
UL 1363A
APPROVED FOR PATIENT CARE VICINITIES APPROVED FOR PATIENT CARE VICINITIES
PS-415-HG-OEM
PS-410-HGOEMCC
PS-415-HGULTRA
PSCLAMP
mounts strips safely,
securely and quickly.
New fast-mount
design!
PS-615-HG-OEM
HGOUTLETCVR
safety covers require a
tool to remove, meeting
code requirements.
IS1800HG Isolation Transformer (front and back)
IS1000HGDV Dual-Voltage Isolation Transformer (front)
Model Output Capacity Nominal AC Voltage UL/IEC Compliance HospitalGrade AC Outlets Cord Length AC Input Plug or Inlet
MedicalGrade Isolation Transformers (For use inside and outside patient care vicinities.)
IS1800HG
1,800W 120V UL 60601-1 6 (5-15/20R HG) 10 ft. 5-20P HG
IS1800HGDV
1,800W 115/230V IEC 60601-1 8 (C13) C20
(1)
IS1000HG
1,000W 120V UL 60601-1 4 (5-15R HG) 10 ft. 5-15P HG
IS1000HGDV
1,000W 115/230V IEC 60601-1 8 (C13) C14
(1)
IS600HGDV
600W 115/230V IEC 60601-1 6 (C13) C14
(1)
IS500HG
500W 120V UL 60601-1 4 (5-15R HG) 10 ft. 5-15P HG
IS300HGDV
300W 115/230V IEC 60601-1 4 (C13) C14
(1)
IS250HG
250W 120V UL 60601-1 2 (5-15R HG) 10 ft. 5-15P HG
(1) Connects to a user-supplied AC input cord and plug compatible with the facility’s wall outlets.
Medical-Grade Isolation Transformers
UL/IEC 60601-1 Compliant
Approved for Use in Patient Care Vicinities
Reduce Cumulative Shock Potential
to Less than 100 µA (Full Isolation)
Medical-grade isolation transformers provide medical-grade regulatory
compliance for connected equipment and are ideal for equipment that does not
require battery backup. Faraday shielding provides full line isolation and reduces
the cumulative leakage current of connected equipment to less than 100 μA for
optimal safety in patient care vicinities, along with continuous noise filtering and
enhanced common mode surge protection.
Dual-voltage models support 115V or 230V at 50/60 Hz, selectable by input power
module fuse installation (both fuses are included with the unit as accessories).
Smaller toroid design provides low impedance line isolation, with pass through,
step up or step down capabilities.
Visit tripplite.com for our full selection,
including power strips rated to 20A.
Model AC Input Voltage AC Output Voltage UL/IEC Compliance AC Outlets Comm. Port AC Input Inlet
OEM Series MedicalGrade Mobile Power Kits (For use as components by OEM manufacturers only.)
HC150SL
120V 120V UL 60601-1 and 1778 1 (C13) USB C14
(3)
HC350SNR
120V 120V UL 60601-1 and 1778 1 (C13) USB C14
(3)
HC150ATD
90-264V 120V UL 60601-1 and 1778 1 (C13) USB C14
(3)
HCINT150SL
230V 230V IEC 60601-1 1 (C13) USB C14
(3)
HCINT350SNR
230V 230V IEC 60601-1 and 62040-1 1 (C13) USB C14
(3)
(3) Connects to a user-supplied AC input cord and plug compatible with the facility’s wall outlets.
Patented
Patient-Protection
Technology
Loading ...
Loading ...
Loading ...