4
Specifications
Gas Supply Requirements
- Australia
- New Zealand
- United Kingdom
Category: II
2H3P
(20, 37).
Flue Type: A
1.
* - Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’
section for details).
Natural Gas LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Connection
See ‘Gas Connection’ information overleaf.
Natural Gas LP Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Connection
See ‘Gas Connection’ information overleaf.
Natural Gas (G20) Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
Heat Input (nett)
Nominal
6.5 kW 5.5 kW 6.5 kW 5.5 kW
Reduced
1.75 kW 1.85 kW 1.75 kW 1.95 kW
Gas Rate (nett)
Nominal
0.69 m
3
/hr 0.58 m
3
/hr 0.51 kg/hr 0.43 kg/hr
Reduced
0.19 m
3
/hr 0.20 m
3
/hr 0.14 kg/hr 0.15 kg/hr
Supply Pressure 20 mbar 37 mbar
Burner Operating Pressure (*) 9.5 mbar
Gas Connection See ‘Gas Connection’ information overleaf.
26 mbar
Pilot
200W 170W 200W 150W
Pilot
0.02 m
3
/hr 0.02 m
3
/hr 0.02 kg/hr 0.01 kg/hr
Loading ...
Loading ...
Loading ...