Loading ...
Loading ...
Loading ...
INSTALLATION - 5591477A855/B
e
It is possible to identify the available gas types based on the country the appliance is to be installed
in. Refer to the heading number to identify the correct values in the “Burner and nozzle characteristics
tables".
Burner and nozzle characteristics tables
5 LPG G30/31
G30/31
28-30/37 mbar
••••••
G30/31
30/30 mbar
••
6 LPG G30/31
G30/31
37 mbar
7 Town Gas G110
G110
8 mbar
••
1 Natural Gas G20 - 20 mbar AUX SR R UR-3c
Rated heating capacity (kW)
1.05 1.8 3.0 3.5
Nozzle diameter (1/100 mm)
72 97 115 133
Pre-chamber (printed on nozzle)
(X) (Z) (Y) (S)
Reduced flow rate (W)
400 500 800 1600
2 Natural Gas G20 - 25 mbar AUX SR R UR-3c
Rated heating capacity (kW)
1.05 1.8 3.0 3.5
Nozzle diameter (1/100 mm)
72 94 113 128
Pre-chamber (printed on nozzle)
(X) (Z) (H8) (S)
Reduced flow rate (W)
400 500 800 1600
3 Natural Gas G25.1 - 25 mbar AUX SR R UR-3c
Rated heating capacity (kW)
1.05 1.8 3.0 3.5
Nozzle diameter (1/100 mm)
77 100 134 145
Pre-chamber (printed on nozzle)
(F1) (Y) (F3) (F3)
Reduced flow rate (W)
400 500 800 1600
4 Natural Gas G2.350 - 13 mbar AUX SR R UR-3c
Rated heating capacity (kW)
1.0 1.8 3.0 3.6
Nozzle diameter (1/100 mm)
94 120 165 200
Pre-chamber (printed on nozzle)
(Y) (Y) (F3) (H3)
Reduced flow rate (W)
400 500 800 1600
5 LPG G30/31 - 30/37 mbar AUX SR R UR-3c
Rated heating capacity (kW)
1.05 1.8 3.0 3.5
Nozzle diameter (1/100 mm)
50 65 85 94
Pre-chamber (printed on nozzle)
----
Reduced flow rate (W)
400 500 800 1600
Rated flow rate G30 (g/h)
76 131 218 255
Rated flow rate G31 (g/h)
75 129 214 250
Gas types IT
GB
IE
FR
BE
ES PT RU
SE
DK
FI
NO
PL HU
Loading ...
Loading ...
Loading ...