2 . Fitting of Heat Shield
When the cook top is installed where the base can be touched, a heat
shield needs to be fitted. This shield must be affixed at least 20mm from
the lower part of the cook top. Refer to Figure 2. Holes drilled into the
heat shield will lower the risk of overheating of the cook top. The holes
should be approximately 25mm in diameter and number around 25.
When installing the cook top above an oven the heat shield is not required.
Cook Top
Figure (2)
Heat shleld
Minimum 20mm
3 Electrical connection
Important electrical installation instructions
The ceramic cook top must be installed by a trained and registered
electrician.
The ceramic cook top must not be mounted above cooling equipment,
dishwashers or rotary dryers.
Any walls surrounding the cooktops are to be heat resistant up top
90
o
C, up to 150mm high, for example, ceramic tiles.
A heat shield must be fitted where access to the underside of to cook
top is possible. Refer to point 2 under Installation section.
The cook top is to be hardwired to the terminal block located in the
centre of the underside of the cook top.
The electrical installer must ensure that the cook top is installed and
complies to relevant local wiring rule requirements. The method of
connection is shown in Figure (3).
The ICC6GE2 is rated at 6.0kW. Minimum 25 amp connection required.