Waldorf GP8450G-CB 800 Series 450mm Gas Griddle Cabinet Base

Installation Operation Manual - Page 27

For GP8450G-CB.

PDF File Manual, 30 pages, Read Online | Download pdf file

GP8450G-CB photo
Loading ...
Loading ...
Loading ...
25
- All Other Markets
NOTE:
(*) Measure burner operating pressure at gas valve outlet test point with burner operating
at 'High' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
(***) - GP8600G Town Gas model is available ex-factory on request only.
Refer to the information in this section for further details.
GP8450G GP8600G GP8900G GP8120G GP8450G
GP8600G
(***)
GP8900G GP8120G
Main Burner Injector 3.00 3.60 3.00 2.85 5.50 7.20 5.50 5.20
Pilot Burner Injector 0.41 0.75
Low Fire Adjustment 1 Full Turn Counter Clockwise from the 'Fully In' Position.
High Fire Adjustment Maximum Flow Screw. Fully Inc.w.
Burner Operating Pressure (*) 0.82 kPa 0.85 kPa 0.90 kPa 0.45 kPa
Supply Pressure 1.13 - 3.40 kPa 0.75 - 1.50 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating
Pressure specified)
GP8450G GP8600G GP8900G GP8120G GP8450G GP8600G GP8900G GP8120G
Main Burner Injector 1.80 2.10 1.80 1.70 1.65 1.95 1.65 1.55
Pilot Burner Injector 0.25 0.25
Low Fire Adjustment 1 Full Turn Counter Clockwise from the 'Fully In' Position.
High Fire Adjustment Maximum Flow Screw. Fully Inc.w.
Burner Operating Pressure (*) 2.6 kPa 2.5 kPa 2.6 kPa 2.6 kPa 2.5 kPa 2.6 kPa
Supply Pressure 2.75 - 4.50 kPa
Gas Regulator Cap Screw
Loading ...