Waldorf GP8450G-CB 800 Series 450mm Gas Griddle Cabinet Base

Installation Operation Manual - Page 26

For GP8450G-CB.

PDF File Manual, 30 pages, Read Online | Download pdf file

GP8450G-CB photo
Loading ...
Loading ...
Loading ...
24
- UK Only
Category: II
2H3P
(20, 37).
Flue Type: A
1.
(*) Gas Control Valve is fitted with a non adjustable maximum flow bypass blanking
screw.
(**) Measure burner operating pressure at the gas control valve outlet test point with
burner operating at High setting. Operating pressure is ex-factory set, through
appliance regulator and is not to be adjusted, apart from when carrying out gas
conversion, if required. (Refer to Gas Conversion information in this section for
details).
GP8450G GP8600G GP8900G GP8120G GP8450G GP8600G GP8900G GP8120G
Main Burner Injector 3.00mm 3.40mm 3.00mm 2.85mm 1.80mm 2.10mm 1.80mm 1.70mm
Pilot Burner Injector 0.41 0.25
Low Fire Adjustment 1 Turn 'Out' c.c.w.
High Fire Adjustment (*) Maximum Flow Screw. Fully In c.w.
Burner Operating Pressure (**) 8.2 mbar 8.5 mbar 8.2 mbar 26 mbar
Supply Pressure 20 mbar 37 mbar
Gas Regulator Cap Screw