Perlick HP24ZO46DL

User Manual - Page 4

For HP24ZO46DL.

PDF File Manual, 12 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
4 | perlick.com
PERLICK RESIDENTIAL UNDERCOUNTER USE & CARE GUIDE
TOUCHSCREEN CONTROL OPERATION  REFRIGERATOR MODELS
OPERATION
MASTER SWITCH
Signature Series products come equipped with a master power
switch located behind the louvered toe kick. Remove the toe
kick to turn power on or o to the unit.
ANTISWEAT HEATER SWITCH
Signature Series-Dual Zone Freezer Models (HP24Z) come
equipped with an anti-sweat heater and switch to enable or
disable the heater. The anti-sweat heater prevents condensation
from forming on the front face of the cabinet between the top
and bottom drawers. Remove the toe kick to access the switch
to enable or disable the anti-sweat heater. The anti-sweat heater
switch is located below the master power switch (Figure 1).
Figure 20
INTERIOR LIGHT
Door units are equipped with an interior light that illuminate
when the door is opened. All models come standard with
adjustable blue and white LED lighting. The cabinet also comes
equipped with a manual light switch for displaying the products
through a glass door.
Always ensure that the manual light switch is in the OFF
position before closing a solid wood or stainless steel door. If
manual light switch is left on for an extended period of time, it
will increase energy usage and decrease LED life.
LOADING PRODUCT
Before storing perishables, turn unit on and allow it to operate
for a minimum of 24 hours to allow temperatures to stabilize.
When loading items into the unit, do not block internal louvers
and fan guard openings or performance will be decreased.
CHECKING PRODUCT TEMPERATURE
1) To accurately check the temperature of product stored in the
refrigerated compartment, insert an accurate thermometer
into a plastic unbreakable bottle, partially lled with water.
Tighten bottle cap securely.
2) Place the bottle in the desired area for 24 hours. Refrain from
opening the unit during the testing period. After 24 hours,
check the temperature of the water. Adjust the temperature
accordingly using the following procedures:
DIGITAL TEMPERATURE CONTROL
Figure 2. Digital Temperature Controller
HP & HH models feature a blue display
HC & HA models feature a red display
Programming Button Denitions:
SET Button
DEFROST button (melting snowake)
UP Arrow
DOWN Arrow
ON/OFF Button
Signature Series Dual-Zone Control Instructions
On/O
Press the ON/OFF button to turn the unit on or o.
Upper Compartment:
To view the upper compartment temperature, press and
release the DEFROST button (melting snowake).
Lower Compartment (Must be coldest zone):
Display reading always shows the lower compartment
temperature.
Figure 1.