08
Overvoltage
Protection
Reverse
Connection
Protection
Condition Steps to Take
1. When the voltage at the output terminal
of the charger is greater than 32V, the
Overvoltage Protection will be triggered.
At this time, the indicator light will go out
and the charger will stop working.
1. When the charger triggers the Reverse
Connection Protection, the external fuse
on the connection line will blow, the
charger will not work normally.
2. Replace the fuse on the connection
line immediately. The specification of the
fuse is 250V 15A.
2. Disconnect the battery immediately
and check the charger.