4. POWER REQUIREMENTS AND SET-UP
WARNING
The system is designed to operate in hostile and demanding situations. Nevertheless it is important to take
extremely care of the AC power supply and set up a proper power distribution.
The system is designed to be GROUNDED. Always use a grounded connection.
PowerCon appliance coupler is a AC mains power disconnection device and must be readily accessible during and
after the installation.
VOLTAGE
The HDL 28-A amplifier is designed to work within the following AC Voltage limits: minimum voltage 100 Volt, maximum
voltage 260 Volt. If the voltage goes below the minimum admitted voltage the system stops working. If the voltage goes
higher than the maximum admitted voltage the system can be seriously damaged. To obtain the best performances from
the system it is very important that the voltage drop it is as low as possible.
CURRENT
The following are the long term and peak current requirement for each HDL 28-A module:
The total current requirement is obtained multiplying the single current requirement by the number of modules. To obtain the best
performances make sure that the total burst current requirement of the system doesn’t create a significant voltage drop on the
cables.
GROUNDING
Make sure that all the system is properly grounded. All the grounding points shall be connected to the same ground
node. This will improve reducing hums in the audio system.
HDL 28-A, AC CABLES DAISY CHAINS
POWERCON IN
POWERCON OUT
Each HDL 28-A module is provided with a Powercon outlet
to daisy chain other modules. The maximum number of
modules that is possible to daisy chain is:
230 VOLT: 6 modules total
115 VOLT: 3 modules total
WARNING - RISK OF FIRE
A superior number of modules in daisy chain will exceed
the Powercon connector maximum ratings and create a
potentially dangerous situation.
POWERING FROM THREE PHASE
When the system is powered from a three phase power distribution it is very important to keep a good balance in the
load of each phase of the AC power. It is very important to include subwoofers and satellites in power distribution
calculation: both subwoofers and satellites shall be distributed between the three phases.
VOLTAGE LONG TERM
230 Volt 3.2 A
115 Volt 6.3 A