5
Water Pressure
A cold water supply with water pressure between 30 psi and 120
psi (207 kPa and 827 kPa) is required to operate the ice maker.
If you have questions about your water pressure, call a licensed,
qualified plumber.
Reverse Osmosis Water Supply
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 psi to 60 psi (276 kPa to 414
kPa).
If the water pressure to the reverse osmosis system is less than
40 psi to 60 psi (276 kPa to 414 kPa), a booster pump can be
inserted into the small tubing that goes from the cold water line
to the reverse osmosis system.
If the ice maker is still not operating properly:
Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
If you have questions about your water pressure, call a licensed,
qualified plumber.
Connect the Water Supply
(on some models)
Read all directions before you begin.
IMPORTANT: If you turn the refrigerator on before the water line
is connected, turn the ice maker off to avoid excessive noise or
damage to the water valve.
Connect the Water Line
1. Unplug refrigerator or disconnect power.
2. Turn off main water supply. Turn on nearest faucet long
enough to clear line of water.
3. Locate a 1/2" to 1¹⁄4" (1.27 cm to 3.18 cm) vertical cold water
pipe near the refrigerator.
IMPORTANT:
Make sure it is a cold water pipe.
Horizontal pipe will work. Drill on the top side of the pipe,
not the bottom. This will help keep water away from the
drill and normal sediment from collecting in the valve.
4. Determine the length of copper tubing you will need.
Measure from the connection on lower left rear of refrigerator
to the water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use
1/4" (6.35 mm) O.D. (outside diameter) copper tubing. Be
sure both ends of copper tubing are cut square.
5. Using a cordless drill, drill a 1/4" (6.35 mm) hole in the cold
water pipe you have selected.
6. Fasten the shutoff valve to the cold water pipe with the pipe
clamp. Be sure the outlet end is solidly in the 1/4" (6.35 mm)
drilled hole in the water pipe and that the washer is under
the pipe clamp. Tighten the packing nut. Tighten the pipe
clamp screws slowly and evenly so washer makes a
watertight seal. Do not overtighten.
7. Slip the compression sleeve and compression nut on the
copper tubing as shown. Insert the end of the tubing into the
outlet end squarely as far as it will go. Screw compression
nut onto outlet end with adjustable wrench.
Do not overtighten.
8. Place the free end of the copper tubing in a container or sink
and turn on the main water supply. Flush the tubing until
water is clear. Turn off the shutoff valve on the water pipe.
Coil the copper tubing.
Connect to Refrigerator
NOTE: On kit models, attach water valve to refrigerator
according to kit instructions.
Style 1
1. Unplug refrigerator or disconnect power.
2. Attach the copper tube to the valve inlet using a
compression nut and sleeve as shown. Tighten the
compression nut. Do not overtighten.
3. Use the tube clamp on the back of the refrigerator to secure
the tubing to the refrigerator as shown. This will help avoid
damage to the tubing when the refrigerator is pushed back
against the wall.
4. Turn shutoff valve ON.
5. Check for leaks. Tighten any connections (including
connections at the valve) or nuts that leak.
6. The ice maker is equipped with a built-in water strainer. If
your water conditions require a second water strainer, install
it in the 1/4" (6.35 mm) water line at either tube connection.
Obtain a water strainer from your nearest appliance dealer.
Style 2
1. Unplug refrigerator or disconnect power.
2. Disconnect the tube clamp on the back of the product and
insert the copper tubing through the clamp as shown.
3. Attach the copper tube to the valve inlet using a
compression nut and sleeve as shown.
4. Tighten the compression nut. Do not overtighten. Reattach
the tube clamp and tube to the back of the cabinet.
5. Turn shutoff valve ON. Check for leaks. Tighten any
connections (including connections at the valve) or nuts that
leak.
6. The ice maker is equipped with a built-in water strainer. If
your water conditions require a second water strainer, install
it in the 1/4" (6.35 mm) water line at either tube connection.
Obtain a water strainer from your nearest appliance dealer.
A
B
C
DFE
G
A. Cold water pipe
B. Pipe clamp
C. Copper tubing
D. Compression nut
E. Compression sleeve
F. Shutoff valve
G. Packing nut
A
C
B
D
E
A. Tube clamp
B. Tube clamp screw
C. Copper tubing
D. Compression nut
E. Valve inlet
A
B
C
A. Tube clamp
B. Copper tubing
C. Compression nut