11 — English
OPERATION
BATTERY PORT LED FUNCTIONS
See Figure 2.
BATTERY PACK LED ACTION
Power On
Without battery pack Solid Red Ready to charge battery pack.
Testing
Hot battery pack
Flashing Red
When battery pack reaches cooled temperature, charger begins charge mode.
Cold battery pack When battery pack reaches warmed temperature, charger begins charge mode.
Error
Error
Flashing Red
and Green
Battery pack or charger error.
Deeply discharged Flashing Red Charger conditions battery until normal voltage is reached, then begins charge mode.
Try to repeat the conditions a second time by removing and reinstalling the battery pack. If the LED error status repeats a second time,
try charging a different battery.
If a different battery charges normally, dispose of the pack that received the error (see your battery pack manual for instructions).
If a different battery also indicates error, the charger should be replaced.
Charging
Fast charging Flashing Green Battery is being charged.
Charged
Battery full Solid Green Charging is complete.
Low Input/Charging Voltage
Low Input Solid Yellow Batteries do not have sufficient charging power to run the connected loads.
GENERATOR CONDITION NOTIFICATIONS
See Figure 4.
IF LCD DISPLAYS: THE CONDITION IS: TO RESOLVE:
HIGH TEMP or LOW TEMP when the
battery is installed for charging.
See figures 4a - 4b.
The battery you are charging is outside
of the acceptable charging temperature
range.
Allow the battery to reach acceptable tem-
perature range. Battery may have to be
removed from the port and reinstalled before
charging will begin.
HIGH TEMPERATURE SHUTDOWN
or LOW TEMPERATURE SHUTDOWN.
See figures 4c - 4d.
The power station is outside of the
acceptable operating temperature range.
Move the power station to a cooler or warmer
area as needed and allow the unit to reach
the acceptable temperature range.
HIGH TEMPERATURE WARNING or
LOW TEMPERATURE WARNING
PRESS RESET. See figures 4e - 4f.
The power station is nearing the maximum
high or minimum low temperature
acceptable to operate.
After allowing time for the power station to
cool or warm to an acceptable temperature,
press the reset button to continue operation.
LOW VOLTAGE SHUTDOWN.
See figure 4g.
The power station’s batteries are
discharged.
Charge the power station. If condition per-
sists, the power station’s batteries should
be replaced.
LOW VOLTAGE WARNING
PRESS RESET.
See figure 4h.
The power station’s batteries do not have
sufficient charge to run the connected
devices.
Disconnect some of the devices. If condition
persists, disconnect all devices and recharge
the power station’s batteries.