Blue Seal Evolution GP518-RB Series 1200mm Gas Griddle Refrigerated Base

Installation Operation Manual - Page 6

For GP518-RB.

PDF File Manual, 29 pages, Read Online | Download pdf file

GP518-RB photo
Loading ...
Loading ...
Loading ...
4
- Australia
- New Zealand Only:
- United Kingdom & EU (CE)
Category: II
2H3P
(20, 37), .II
2H3B/P
(20, 28-30),
Flue Type: A
1.
* - Measure burner operating pressure at gas control valve outlet test point with burner operating at
Highsetting. Operating pressure is ex-factory set, through the appliance regulator and not to
be adjusted, apart from when converting between gases, if required. (Refer to Gas Conversion
section for details).
For Refrigeration Cabinet Specifications refer to Refrigeration Cabinet Installation and Operation
Manual supplied with appliance.
GP513 GP514 GP516 GP518
GP513 GP514 GP516 GP518
Heat Input (nett) 10.5 kW 13.3 kW 21 kW 28.5 kW 10.5 kW 13.3 kW 21 kW 28.5 kW
Gas Rate (nett) 1.11 m
3
/hr 1.41 m
3
/hr 2.22 m
3
/hr 3.02 m
3
/hr 0.81 kg/hr 1.03 kg/hr 1.63 kg/hr 2.21 kg/hr
Supply Pressure 20 mbar 37 mbar
Burner Operating Pressure (*) 8.2 mbar 8.5 mbar 8.2 mbar 26 mbar
Gas Connection
3
/
4
BSP Male
GP513 GP514 GP516 GP518 GP513 GP514 GP516 GP518
Input Rating (N.H.G.C.)
40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr 40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.90 kPa 0.85 kPa 0.90 kPa 2.6 kPa 2.5 kPa 2.6 kPa
Gas Connection ¾BSP Male
GP513 GP514 GP516 GP518 GP513 GP514 GP516 GP518
Input Rating (N.H.G.C.)
40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr 40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.90 kPa 0.85 kPa 0.90 kPa 2.6 kPa 2.5 kPa 2.6 kPa
Gas Connection ¾BSP Male
GP513 GP514 GP516 GP518
Heat Input (nett) 12.0 kW 16.0 kW 24.0 kW 32.5 kW
Gas Rate (nett) 0.95 kg/hr 1.26 kg/hr 1.89 kg/hr 2.56 kg/hr
Supply Pressure 28 - 30 mbar
Burner Operating Pressure (*) 26 mbar
Gas Connection
3
/
4
BSP Male