VC Series Manual 35
Temperatures Available with a Controller
The water heater can deliver water at only one temperature seng at a me. The available temperatures are
provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the On/Obuon
for 5 seconds while the water heater is OFF.
These temperatures are suggesons only:
* Temperature sengs from 125-140 °F (52-60 °C) are available by seng switch 6 to ON in the SW1 Dip
switch (tan switches). These models have a default maximum temperature of 120° F (49° C) and an opon
(switch 6) to increase the maximum temperature to 140 °F (60 °C).
DO NOT adjust the other switches unless specically instructed to do so.
WARNING
Kitchen 120 °F (49° C)
Shower 98 - 110 °F (37 - 43 °C)
Bath Fill 102 - 110 °F (39 - 43 °C)
Temperature Sengs Available (Fahrenheit °F)
RL75i, RL75e
98 100 102 104 106 108 110 115 120
125
*
130
*
135
*
140
*
150
**
160
**
RL94i, RLX94i,
RL94e
185**
Celsius °C 37 38 39 40 41 42 43 46 49 52 54 57 60 66 71 85
** These sengs require the MCC-91-2 controller. When the MCC-91-2 controller is connected, these higher
temperatures are available on all controller models in the system. Use of an MCC-91-2 controller in a
residenal dwelling will reduce the warranty coverage to that of a commercial warranty applicaon.
Alternate Temperature Sengs
A dierent range of temperature sengs is available by seng switches 2 and 3 of the SW2 dip switch (white
switches) to ON. The table below shows the sengs available with the MC-91-2 and MCC-91-2 controller.
Alternate Temperature Sengs Available (Fahrenheit °F)
RL75i, RL75e
110 115 120 125 130 135 140 145 150 155 160
RL94i, RLX94i, RL94e
165 170 175 180 185
Celsius °C 43 46 49 52 54 57 60 63 66 68 71 74 77 79 82 85
MC-91-2
MCC-91-2
MC‐91‐1, MCC‐91‐1, MC100V‐1, and BC100V‐1 controllers are not compable with
Alternate Temperature Sengs. Alternate Temperature Sengs are for commercial
applicaons only.
DO NOT use the MC‐91‐1, MCC‐91‐1, MC‐100V‐1, or BC‐100V‐1 controllers when dip
switches 2 and 3 (white switches) are in the ON posion.
WARNING