No. Symbol LED Digital Display Explanation
23 Ht.F Heat mode of SCOP test condition F
24 Ht.H Heat mode of SCOP test condition H
25 Ht.I Heat mode of SCOP test condition I
26 Ht.J Heat mode of SCOP test condition J
27 qut Quit
28 Frq Frequency (speed of compressor, equals revolutions per
second (RPS) ) .
29 opN Electronic expansion valve opening
29 I.FN Indoor unit fan speed level
30 o. FN Indoor unit fan speed level
31 tAo Temperature of outdoor ambient
32 tc Temperature of outdoor condenser
33 td Temperature of outdoor discharge
34 tE Temperature of outdoor defrost
35 tS Temperature of outdoor suction
36 tdr Temperature of compressor driver module
37 Idr Current of the compressor
38 tH Temperature of heat water (reserved)
39 tAI Temperature of indoor ambient
40 TCI Temperature of indoor condenser
41 tSt Setting temperature on indoor unit
42 UN UN=UNIT, 1UN means with 1 indoor unit:
2UN means with 2 indoor unit, MAXI application
43 r32 Refrigerant R32
44 OiL Unit gets compressor oil recycling mode