16 - INSTALLATION 91477A830/B
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the cock
spindle clockwise all the way.
Lubricating the gas cocks
Over time the gas cocks may become difficult to
turn and get blocked. Clean them internally and
replace the lubrication grease.
Burner and nozzle characteristics table (60 cm models)
The nozzles not provided are available at Authorised Service Centres.
Burner and nozzle characteristics table (70-90 cm models)
The nozzles not provided are available at Authorised Service Centres.
Electrical connection
General information
Check the mains characteristics against the data
indicated on the plate.
The identification plate bearing the technical
data, serial number and brand name is visibly
positioned on the appliance.
Do not remove this plate for any reason.
The appliance must be connected to ground
using a wire that is at least 20 mm longer than
the other wires.
The appliance can work in the following modes:
Following adjustment to a gas other
than the one originally set in the factory,
replace the gas setting label on the
appliance with the one corresponding
to the new gas. The label is inserted
inside the nozzle pack (where present).
Lubrication of the gas cocks should be
performed by a specialised technician.
1 Natural Gas G20 - 20 mbar AUX SR UR2
Rated heating capacity (kW) 1.0 1.8 3.6
Nozzle diameter (1/100 mm) 72 97 140
Pre-chamber (printed on nozzle) (X) (Z) (H3)
Reduced flow rate (W) 400 500 1400
2 LPG G30/31 - 30/37 mbar AUX SR UR2
Rated heating capacity (kW) 1.0 1.7 3.6
Nozzle diameter (1/100 mm) 50 65 96
Pre-chamber (printed on nozzle) - - (S4)
Reduced flow rate (W) 400 500 1600
Rated flow rate G30 (g/h) 73 124 265
Rated flow rate G31 (g/h) 71 121 257
1 Natural Gas G20 - 20 mbar AUX SR RR UR2
Rated heating capacity (kW) 1.0 1.8 2.6 4.0
Nozzle diameter (1/100 mm) 72 97 108 150
Pre-chamber (printed on nozzle) (X) (Z) (Y) (H3)
Reduced flow rate (W) 400 500 800 1800
2 LPG G30/31 - 30/37 mbar AUX SR RR UR2
Rated heating capacity (kW) 1.0 1.7 2.6 3.8
Nozzle diameter (1/100 mm) 50 65 81 98
Pre-chamber (printed on nozzle) - - - (S4)
Reduced flow rate (W) 400 500 800 1600
Rated flow rate G30 (g/h) 73 124 189 276
Rated flow rate G31 (g/h) 71 121 186 271
See General safety instructions.