Lifesmart LS143 General Controller

Instructions - Page 3

For LS143.

PDF File Manual, 4 pages, Read Online | Download pdf file

LS143 photo
Loading ...
Loading ...
General Controller LS143
WIRING PLAN - DC Motor WIRING PLAN - Three-way Switch
Copyright © 2020 LifeSmart Inc. All Rights Reserved.
Facebook: ilifesmarthome
Twitter: ilifesmarthome
The on/off status of CH1, CH2 and CH3 depends
on the connection of K1/K2/K3.
Connected to the power resource parallel.
CH1 and CH2 is connected to each interface of the DC
motor separately.
COM+ is normally open, and connected to the
public interface of the motor, and is disconnect-
ed with CH1, CH2 and CH3 in default. If the control
item is on then it is connected. It can be powered
by GND.
COM- is normally closed and connected with
CH1 and CH2 in default. If the control item is on
then it is disconnected.. It can be powered by
DC+.
K1
K2
K3
CND
DC+
CH1
CH2
CH3
COM+
COM-
Universal Control Board
Power Resource Interface
Configuration Button
The on/off status of CH1, CH2 and CH3 depends
on the connection of K1/K2/K3.
1. Connected to the power resource parallel.
2. Power the sensor using GND/0V and 12V/24V.
3. If the sensor has a power resource itself, the
sensor also can power the Universal Control Board
using the DC input.
It can connect to three different output interfaces here.
The control channels with CH1, CH2 and CH3 can work
independently.
COM+ is normally open, and disconnected with
CH1, CH2 and CH3 in default. If the control item
is on then it is connected.
COM- is normally closed, and connected with
CH1,CH2 and CH3 in default. If the control item
is on then it is disconnected.
K1
K2
K3
CND
DC+
CH1
CH2
CH3
COM+
COM-
Universal Control Board
Power Resource Interface
Configuration Button
Loading ...