GAS SUPPLY REQUIREMENTS
5. GAS SUPPLY REQUIREMENTS
Installation of this range must conform with local codes, or in the absence of local codes, with national Fuel Gas
Code, ANSIZ223.1 / NFPA 54.
In Canada, installation must conform to the current natural Gas Installation /code, CAN 1-1.1-M81 and with local
codes where applicable.
This range has been design-certified according to ANSIZ21.1a, latest edition.
Reading LP in. w.c.
NG (Natural Gas)
in. w.c
Maximum gas pressure
11.0
10.0
7.0
5.0
Appliance Regulator Setting
for outlet pressure
SAFETY TIPS FOR GAS OPERATION
Keep appliance area clear and free from combustible materials, gasoline, and nonflammable vapors.
Do not obstruct the flow of combustion air into the range and ventilation air away from the range.
Ventilation: it is a must that the unit be set under a powered, vented exhaust hood of sufficient size and
capacity.
Before installing the range, you must locate and secure the included anti-tip bracket to the wall for your
range.
CAUTION
The use of cabinets for storage above the appliance may result in a potential burn hazard. Combustible
items may ignite; metallic items may become hot and cause burns. If a cabinet storage is to be provided,
the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7cm)
beyond the bottom of the cabinets.