Installation
Electrical connection
• WARNING- THIS APPLIANCE MUST BE EARTHED
• This appliance is designed to be connected to a 220-240V~50Hz AC electricity
supply.
• Before proceeding with the electrical connection, verify that the current
carrying capacity of the system and the isolator / main switch is adequate for
the maximum power rating of the oven.
• Electrical installation of the residence and of the appliance’s isolator must be
earthed and conform with the required safety regulations.
• If there is no suitable circuit and a fused switch, they must be installed
by a qualified electrician before the hob is connected.
• An isolator switch must be easily accessible once the oven has been installed.
• Do not use adaptors, multiple sockets and/or extension leads.
• A circuit breaker with a contact opening of at least 3 mm, rated 32A and
delayed functioning type must be installed inside the supply circuit.
• During installation, please ensure that insulated cables are used. An incorrect
connection might damage your appliance and will void the manufacturer’s
guarantee.
• All repairs must be carried out by an authorised service personal or a
qualified electrician.
• Switch off/isolate your appliance before each maintenance.
• The GREEN/YELLOW wire is the EARTH and must be connected to the
terminal which is marked with the letter E or by the earth symbol or
coloured GREEN or GREEN/YELLOW.
• The BLUE wire is the NEUTRAL and must be connected to the terminal
marked with the letter N or coloured BLACK.
• The BROWN wire is the LIVE wire and must be connected to the
terminal marked with the letter L or coloured RED.