Jenn-Air JGRP536WP00 36" dual-fuel range stainless

User Manual - Page 6

For JGRP536WP00.

PDF File Manual, 64 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Electrical
Shock
Hazard
Plug
into
a
grounded
3
prong
outlet.
Do
not
remove
ground
prong.
Do
not
use
an
adapter.
Do
not
use
an
extension
cord.
Failure
to
follow
these
instructions
can
result
in
death,
fire,
or
electrical
shock.
IMPORTANT:
The
range
must
be
electrically
grounded
in
accordance
with
local
codes
and
ordinances,
or
in
the
absence
of
local
codes,
with
the
National
Electrical
Code,
ANSI/NFPA
70
or
Canadian
Electrical
Code,
CSA
C22.1.
If
codes
permit
and
a
separate
ground
wire
is
used,
it
is
recommended
that
a
qualified
electrical
installer
determine
that
the
ground
path
is
adequate.
A
copy
of
the
above
code
standards
can
be
obtained
from:
National
Fire
Protection
Association
One
Batterymarch
Park
Quincy,
MA
02269
CSA
International
8501
East
Pleasant
Valley
Road
Cleveland,
OH
44131-5575
mw
A120
volt,
60
Hz.,
AC
only,
15-amp
fused,
electrical
circuit
is
required.
A
time-delay
fuse
or
circuit
breaker
is
also
recommended.
It
is
recommended
that
a
separate
circuit
serving
only
this
range
be
provided.
gm
Electronic
ignition
systems
operate
within
wide
voltage
limits,
but
proper
grounding
and
polarity
are
necessary.
Check
that
the
outlet
provides
120-volt
power
and
is
correctly
grounded.
gm
Thewiring
diagram
is
located
behind
the
kick
plate
in
a
clear
plastic
bag.
Explosion
Hazard
Use
a
new
CSA
International
approved
gas
supply
line.
Install
a
shut-off
valve.
Securely
tighten
all
gas
connections.
If
connected
to
LP,
have
a
qualified
person
make
sure
gas
pressure
does
not
exceed
14"
(36
cm) water
column.
Examples
of
a
qualified
person
include:
licensed
heating
personnel,
authorized
gas
company
personnel,
and
authorized
service
personnel.
Failure
to
do
so
can
result
in
death,
explosion,
or
fire.
Observe
all
governing
codes
and
ordinances.
IMPORTANT:
This
installation
must
conform
with
all
local
codes
and
ordinances.
In
the
absence
of
local
codes,
installation
must
conform
with
American
National
Standard,
National
Fuel
Gas
Code
ANSI
Z223.1/NFPA
54
-
latest
edition
or
CAN/CGA
B149
-
latest
edition.
IMPORTANT:
Range
must
be
connected
to
a
regulated
gas
supply.
IMPORTANT:
Leak
testing
of
the
range
must
be
conducted
according
to
the
manufacturer’s
instructions.
Type
of
Gas
Natural
Gas:
This
range
is
design-certified
by
CSA
International
for
use
with
Natural
gas
or,
after
proper
conversion,
for
use
with
LP
gas.
mg
This
range
is
factory
set
for
use
with
Natural
gas.
The
model/
serial
rating plate
located
under
the
console
on
the
right-hand
side
has
information
on
the
types
of
gas
that
can
be
used.
If
the
types
of
gas
listed
do
not
include
the
type
of
gas
available,
check
with
the
local
gas
supplier.
LP
Gas
conversion:
Conversion
must
be
done
by
a
qualified
service
technician.
No
attempt
shall
be
made
to
convert
the
range
from
the
gas
specified
on
the
model/serial
rating
plate
for
use
with
a
different
gas
without
consulting
the
serving
gas
supplier.
To
convert
to
LP
gas,
use
the
LP
gas
conversion
kit
provided
with
your
range
and
see
the
“Gas
Conversions”
section.
The
parts
for
this
kit
are
in
the
literature
package
supplied
with
the
range.
Loading ...
Loading ...
Loading ...