Loading ...
Loading ...
Loading ...
16
www.bromicheating.com
Directions for use
Automatic controls are safety devices and shall not be
opened. The manufacturer’s responsibility and guarantee
are invalid if the control is unduly opened.
A regulation shutdown must occur every 24hours to
enable the unit to check its own efficiency (systems for
non permanent operation)
Connect and disconnect the unit only after switching off
the power supply
Avoid exposing the unit to dripping water
Ventilation and the lowest temperature ensures the
longest life of the control
Electrical Installation
Live and Neutral should be connected correctly; a mistake
could cause a dangerous situation.
Before starting the system check cables carefully for
incorrect installation
The earth terminal of the control, the metal frame of the
burner and the earth on the mains supply must be well
connected
OPERATION DATA - HONEYWELL CONTROL BOX CONTINUED...
Operation
At every start, the control unit proceeds to a self-checking
of its own components. During the pre-purge or waiting
time (TW) the internal circuit makes a test of the flame signal
amplifier. Extraneous light or fault in the amplifier will result
in the simulation of a flame which will prevent the control
from starting.
At the end of the waiting or pre-purge time, the gas valve is
energised and the ignition device is operated. In this way, the
safety time (TS) begins.
If a flame is detected during the safety time, the ignition
device is inhibited and the gas valve remains energised.
If the control does not detect any flame signal during the
safety time, at the end of safety time (TS), the unit proceeds
to lockout and the gas valve and ignition device are switched
off.
If the established flame signal is lost, (during the safety time
or during operation thereafter) this will cause the ignition
device to be reactivated within 1 second.
If the burner does not light within 25 seconds of ignition
reactivation, the heater will enter failure lockout mode and
must be reset.
OPERATION DATA HONEYWELL VALVE:
The VK series gas control have been specially developed for
application in domestic appliances. The Honeywell Gas Valve
is a multi-functional control which incorporates an adjustable
direct acting pressure regulator. It is designed for operation
on 220/240V.
Standard Specifications
1/2” G Female Pipe Thread connection
Ambient Temperature Range of 0°C to 60°C
Compact Size: 86.5mm x 63.5mm x 65.9mm
50mb Pressure Rating
1/2” x 1/2” (BSP- G) Inlet and Outlet
Earthing terminal – 6mm spade tab
Tamper resistant screws
Top mounted coils that can be field replaced
TECHNICAL DATA
Max inlet working pressure 50 mbar
Installation group Group 2
Operating Temperature 0°C to 60°C
Voltage Ratings 220/240VAC
50/60Hz .52A
Adjust Regulator Pressure
Unscrew the regulator cover.
Unscrew the outlet plug to measure the outlet regulator
pressure by using manometer.
Adjust the pressure by turning the regulator screw
clockwise or anti wise.
Adjust the pressure according to appliance specification.
Inlet Pressure test point
Outlet Pressure test point
Regulator
IMPORTANT
Remember to place the regulator cover, outlet and inlet back
on.
!
Loading ...
Loading ...
Loading ...